background image

16

 

 

 

 

 

PROBLEM

No  sound  from  the  unit.  The 
SIGNAL LED does not light up.

Full power cannot be obtained. The 
LIMIT LED never lights up.

Sound is distorted. The LIMIT LED 
is  not  on,  or  only  lights  up 
occasionally.

Sound  is  distorted  and  very  loud 
and LIMIT LED lights up.

Hum  or  buzz  when  a  mixer  is 
connected to the unit.

Hum  or  buzz  when  using  lighting 
controls in the same building.

The ON LED does not light up when 
the  mains  connector  is  connected 
and the unit is switched to ON.

 

CAUSE

1 – The signal source is sending no 
signal.
2 – Defective cable.

The signal source does not have a 
hot enough output.

The  mixer  or  signal  source  is 
distorting.

The system is overloaded and has 
reached maximum power.

1.– The console probably has un-
balanced outputs. You may be using 
an  incorrect  un-balanced  to 
balanced cable.
2.–  The  mixer  and  the  powered 
speaker  are  not  plugged  into  the 
same mains outlet.
3.–  The  audio  signal  cable  is  too 
long or too close to an AC cable

1.–  The  audio  signal  cable  is  too 
long  or  too  close  to  the  lighting 
cable.

2.– On a sound system with three-
phase  AC,  the  lighting  equipment 
and the UNIT are connected to the 
same phase.
1.– Bad or loose AC connection to 
the UNIT or the mains outlet.
2 – Faulty AC cable.

 

SOLUTION

1 – Check that the mixer or sound 
source is sending signal to the UNIT.
2 – Check that the cable from the 
sound  source  to  the  UNIT  is 
connected  correctly.  Replace  the 
cable if defective.

If using a mixer, use the balanced 
o u t p u t   i f   a v a i l a b l e .   U s e   a 
professional  mixer  with  a  hotter 
output.

Turn  mixer  channel  gains  down. 
Check  that  none  of  your  signal 
sources are distorting.

Turn down the mixer's output.

1.–  Read  the  appendix  of  this 
manual  to  make  a  correct  un-
balanced to balanced cable.

2.– Connect the mixer and the unit 
to the same mains outlet.

3.– Use a cable that is as short as 
possible  and/or  move  the  audio 
signal  cable  away  from  mains 
cables.
1.–  Move  the  audio  signal  cable 
away from lighting cables. Try to find 
out at what point the noise is leaking 
into the system.
2.– Connect the sound system to a 
different phase than the lights. You 
may need the help of an electrician.

1.– Check your connections.

2.–  Check  the  cables,  connectors 
and AC power with a suitable mains 
tester.

Troubleshooting

 

 

 

Manual del Usuario

 / artec 500 series / 

User’s Manual

Summary of Contents for ARTEC 500 Series

Page 1: ...ser s Manual Antes de utilizar el equipo lea la secci n Precauciones de seguridad de este manual Conserveestemanualparafuturasconsultas Before operating the device please read the Safety precautions s...

Page 2: ...WINGS 3 4 5 12 18 17 ACCESSORIES ANNEX CONFIGURATIONS Line connections unbalanced and balanced SAFETY PRECAUTIONS WARRANTY DECLARATION OF CONFORMITY 14 16 AMPLIFIER Description ON OFF Overload indicat...

Page 3: ...of a flexible cable already prepared Si el aparato es conectado permanentemente la instalaci n el ctrica del edificio debe incorporar un interruptor multipolar con separaci n de contacto de al menos...

Page 4: ...araci n en garant a es imprescindible que el producto no haya sido previamente manipulado e incluir una fotocopia de la factura de compra All our products are warrantied against any manufacturing defe...

Page 5: ...Part 2 Immunity l EN 50581 2012 Technical documentation for the assessment of electrical and electronic products with respect to the restriction of hazardous substances Cumple con los objetivos esenc...

Page 6: ...other systems in this market segment High frequencies are handled by the M 60N compression driver with 1 exit and titanium diaphragm offering excellent performance The birch plywood cabinet construct...

Page 7: ...uction offers an ultra compact design which is available in black or white ARTEC S15A Powered subwoofer system High output 15 louspeaker Loop Thru connections Filtered output defeat switch Variable LP...

Page 8: ...CONFIGURATIONS 4 x ARTEC 506A 230 1 x ARTEC S15A 230 Standard Configuration DSP 2040 From mixer POWER SUPPLY LINK LINK POWER SUPPLY POWER SUPPLY 8 Manual del Usuario artec 500 series User s Manual...

Page 9: ...ATIONS cont d 4 x ARTEC 508A 115 2 x ARTEC S15A 115 Standard Configuration DSP 2040 From mixer LINK LINK POWER SUPPLY POWER SUPPLY POWER SUPPLY POWER SUPPLY 9 Manual del Usuario artec 500 series User...

Page 10: ...TIONS cont d 4 x ARTEC 510A 230 2 x ARTEC S15A 230 Standard Configuration DSP 2040 From mixer LINK POWER SUPPLY POWER SUPPLY LINK POWER SUPPLY POWER SUPPLY 10 Manual del Usuario artec 500 series User...

Page 11: ...TIONS cont d 4 x ARTEC 526A 115 2 x ARTEC S15A 115 Standard Configuration DSP 2040 From mixer LINK POWER SUPPLY POWER SUPPLY LINK POWER SUPPLY POWER SUPPLY 11 Manual del Usuario artec 500 series User...

Page 12: ...A ARTEC 508A Bottom View Right View Front View Rear View Rear View Bottom View Right View Front View Rear View Top View Right View Front View Bottom View Right View Front View Rear View Top View Right...

Page 13: ...z 38 x 19 5 x 25 5 cm 15 x 7 7 x 10 in 9 kg 19 8 lb TRD 2 AXC ZT TRD 6 AXC ZT ANL 2 AXW 1 AXU AR506 AXR AR5 ARTEC 510A 720 W peak 360 W continuous Class D Bi amplified Balanced Differential Line Line...

Page 14: ...between two types of frequency response 7 LOW PASS CROSSOVER only ARTEC S15A Button for LPF adjustment for subwoofer We recommend 100 Hz 8 MIC LINE Button for switching between microphone and line sen...

Page 15: ...n acceptable levels are regained the unit will switch back on automatically Therefore the current consumed by a 115V version is double the 230V version to achieve the same acoustic power level Normall...

Page 16: ...ound system with three phase AC the lighting equipment and the UNIT are connected to the same phase 1 Bad or loose AC connection to the UNIT or the mains outlet 2 Faulty AC cable SOLUTION 1 Check that...

Page 17: ...only For other wall materials source the suitable wall plug before use DAS Audio Group S L is not responsible for use other than the recommended or whether it be the result of insufficient strength o...

Page 18: ...n the same way At the device s input the two signals get summed with opposite sign so that noise is cancelled out while the programme signal doubles in level Most professional audio devices use balanc...

Page 19: ...8 DAS 4 USA DAS Audio Asia PTE LTD 3 Temasek Avenue Centennial Tower 34 36 Singapore 039190 Tel 65 6549 7760 DAS Audio Group S L C Islas Baleares 24 46988 Fuente del Jarro Valencia SPAIN Tel 34 96 134...