Re f r i g e r a n t   C h i l l e r   M a n u a l

  

w w w.t h e a q u a r i u m s o l u t i o n .c o m 

4

SPECIFICATIONS

EXAMPLE PERFORMANCE CURVES

DC300

DC750

DC2200

DC4000

Voltage

220-240V

220-240V

220-240V

220-240V

Frequency

50Hz

50Hz

50Hz

50Hz

Working Current

0.8 A

1.8 A (3.0A)

3.2 A

7A

Power

1/15HP

1/4HP

1HP

2HP

Cooling Wattage

300W

750W

2200W

4000W

Water Flow Rate

200-1000L/h

1000-2500L/h

1000-2500L/h

3000-6000L/h

Refrigerant

R134a

R134a

R134a

R407C

Refrigerant Weight

120g

170g

600-650g

800-1000g

Weight

9.5Kg

18.6Kg

31.3Kg

47Kg

Dimensions (mm)

338x218x325

448x330x440

520x400x480

634x4680x590

Water Volume Cooling Examples

Ambient Room Temperature

30ºC

30ºC

30ºC

30ºC

Water Temperature Before Refrigeration

28°C

28°C

28°C

28°C

Refrigeration Time

20h 

20h

20h

20h

Water Volume Refrigerated (Example A)

150L

300L

1000L

2000L

Water Temperature After Refrigeration 

18°C

18°C

16°C

16ºC

Water Volume Refrigerated (Example B)

300L

600L

2000L

4000L

Water Temperature After Refrigeration 

22°C

22°C

22°C

22°C

1.   The rate of flow is dictated by the duty of the pump or water supply system which must be purchased in 

addition to the chiller. 

2.   The refrigeration performance test is carried out at an ambient temperature of 30°C without any other 

additional heat sources.

3.   The cooling rate and efficiency will be affected by the installation location and any heat sources, such as 

heat from lighting or pumps.

4.   Refrigeration efficiency will decrease when there  is insufficient ventilation within the cabinet or room due  

to heat from the unit.  

The refrigeration performance test is carried out at an ambient temperature of 30°C without any other additional 
heat sources.

AMBIENT TEMPERATURE: 30°C. INITIAL WATER TEMPERATURE 28ºC.   
REFRIGERATED WATER VOLUME: DC300 - 150L, DC750 - 300L, DC2200 - 1000L, DC4000 - 2000L

Summary of Contents for DC2200

Page 1: ...Refrigerant Chiller P R O D U C T U S E R M A N U A L For DC300 DC750 DC2200 DC4000 ...

Page 2: ... TO SIMPLE PROBLEM SOLVING 10 WARRANTY 10 PARTS LIST 1 Front filter cover 2 Filter Front filter models only 3 Control panel 4 Front cover 5 Circuit board 6 Tank with evaporator 7 Seal sleeve 8 Filter side filter models only 9 Side filter cover 10 Middle cover with power supply switch DC300 DC750 only 11 Water inlet and outlet adaptor 12 Nut 13 Handle where applicable 14 Back cover 15 Condenser 16 ...

Page 3: ...ure titanium evaporator for both fresh salt water use 5 Over current protection device system 6 Temperature memory system automatically returning to the previously set temperature following a power failure to protect the fish in the aquarium ADDITIONAL FEATURES DC4000 1 Integrated heating and cooling system Unit can be used for heating in the winter and cooling in the summer but do not operate at ...

Page 4: ...1000L 2000L Water Temperature After Refrigeration 18 C 18 C 16 C 16ºC Water Volume Refrigerated Example B 300L 600L 2000L 4000L Water Temperature After Refrigeration 22 C 22 C 22 C 22 C 1 The rate of flow is dictated by the duty of the pump or water supply system which must be purchased in addition to the chiller 2 The refrigeration performance test is carried out at an ambient temperature of 30 C...

Page 5: ...le sources high temperature direct sunshine moisture or dust Fig 2 3 Place the unit on a horizontal stable surface Fig 3 4 Install at least 20 40cm away from any wall or structure for venting Fig 4 5 Do not cover the chiller whilst it is working avoid shaking or colliding with other objects directly 6 This chiller does not have a built in water pump and so a suitable pump to circulate water is req...

Page 6: ...gs are in alignment with the grilles on the chiller and that the air outlet grille on the cabinet is made as high as possible to efficiently expel the hot air The chiller should be installed with its back as near as possible to the grille of the cabinet to allow fresh air circulation For the best air circulation it is suggested to install your chiller outside of the aquarium cabinet If the chiller...

Page 7: ...ollow the standard set temperature adjustment instructions above Temperature adjustment is available between 3ºC to 46ºC To adjust the heating temperature press HEAT for 3 seconds and then follow the standard set temperature adjustment instructions above Scroll through the modes with the arrows TPS will be shown on the display to indicate the heating temperature is enabled Temperature adjustment i...

Page 8: ...troller then the chiller will see this as a reset and delay for 3 minutes before starting the compressor AUTOMATIC ON OFF SWITCHING OF THE REFRIGERATION COMPRESSOR When the refrigeration compressor has not been running for over three minutes and the water temperature is 1 ºC above the set temperature the compressor will start to work again automatically The compressor will continue to run and cool...

Page 9: ... dry soft cloth Fig 3 4 NEVER immerse the unit into water or flush it directly with water to prevent damage to the electric insulation of the chiller Fig 4 5 Disconnect the power supply plug if the unit is not to be used for a long time Remove the inlet outlet pipes and tilt the front of the chiller to remove water from the unit Clean all of the parts with a soft cloth and cover it with a plastic ...

Page 10: ...s not run and the display is dead Power not turned on Loose plug The fuse has blown Turn on the power Be sure the power cord is fully plugged in Change for a new fuse The chiller switches on and off Connected to wrong voltage and or frequency Connect to correct power source according to the name plate Refrigeration capacity reduces or even no refrigeration The chiller protection device is operatin...

Page 11: ...FOLLOW US FOR INSPIRATION www theaquariumsolution com TheAquariumSoln fb com theaquariumsolution fb com groups theaquariumsolution ...

Reviews: