background image

18 

 

Version 1.0 

Time setting 

The unit should automatically sync to the correct time when setup and keep the correct time during a 
power outage. If the time is incorrect and needs to be adjusted tap on ‘Time Setting’ and select ‘Time 
Sync’. It is normal for the ‘Firmware time’ to lag behind the ‘App Time’ by 1-5 seconds due to the time 
taken to process data between the app and the device. 

 

Connect to controller 

This option is unused at the moment. 

 

Flow Calibration 

Used to calibrate the unit to ensure accurate dosing. Please see Calibration in this manual. 

 

Factory Settings Reset 

Use this function to factory reset the unit. This will remove all programmed settings from the unit. To 
reset the unit, tap on ‘Factory Settings Reset’ and select reset. The unit will beep and temporally go 
offline. When the status light returns to solid red the unit is reset. This will not remove the unit from 
the app or cloud. Do not power off the unit during this process. 

 

Remove Device 

To remove the device from the app tap on ‘Remove Device’ and select remove. The unit will still be 
connected to the associated router and the Cloud. The D-D P4 Pro can be added back to a mobile 
device with the Kamoer Remote App installed by tapping on the ‘+’ symbol on the devices page and 
choosing it from the ‘Local Devices’. 

 

 

 

 

 

 

 

 

 

 

 

 

w

w

w

.th

ea

qu

ari

um

slu

tio

n.c

om

 

Summary of Contents for H2Ocean P4

Page 1: ...P4 CLOUD DOSING PUMP USER MANUAL...

Page 2: ...ter your cloud account 5 Connect your dosing pump to the cloud 6 Programming the dosing pump 7 Setting the dosing plans 8 Advanced plan adjustments 11 Manual Addition 14 Calibration 15 Advanced Settin...

Page 3: ...resistance and ozone UV resistance Up to 24 dosing plans per day per channel 1 99 day cycle dosing per channel or specified weekly dosing per channel Each channel can be individually calibrated D D P...

Page 4: ...ture development 8 Power input DC 12V Indicator Status Description Status indicator Red On Connected to the Cloud via router Off Disconnected from the router Fast Flashing Pump is in configuration mod...

Page 5: ...installation Please note the pump heads on the doser can be removed and rotated to do this press the blue tabs on the side of the head and carefully pull the head away from the pump The head can then...

Page 6: ...You will need to register an account and login on the Kamoer remote app before using your dosing pump Choose to register via E mail or mobile then follow the onscreen instructions to complete registra...

Page 7: ...s into two separate 2 4 and 5ghz networks before attempting to connect the pump Connect the power supply to the DC 12v socket on the side of the dosing pump and plug in to a mains power source After t...

Page 8: ...dosing pump To Program the dosing pump open the Kamoer Remote App and select the device you want to program from the available devices list With the device selected the main plan page will be displaye...

Page 9: ...dose for a limited period e g between 10 00 and 18 00 Once the times have been set tap Save in the top right corner Select the Quick Add tab Enter the total amount that you would like to dose during t...

Page 10: ...un as described above but the second channel will start its first dose at 12 03 and then continue with an automatically programmed 3 minutes delay on every dose When finished tap Save in the top right...

Page 11: ...ump 1 has been set to dose every three days a total of 10ml over 24 smaller doses between 00 00 and 23 59 The dosing container has 999 6ml of solution left in it and should therefore last approximatel...

Page 12: ...ount as required select Save to confirm the change It is only possible to set a time within the period set for the plan group Plan points will always be displayed in time order If two points are set a...

Page 13: ...n group period it is best to delete the existing Group plan by swiping the plan to the left and set up a new one as described in this manual Plan points can be added to an existing group by selecting...

Page 14: ...ted Tap Save to confirm the changes Once saved any existing plan points for that group will be overwritten Multiple plan groups can be added to the same pump This will allow different plans to be set...

Page 15: ...ices list In the Plan page tap the Manual icon at the bottom middle of the screen This will open the manual settings page Tap on the pump that you would like to set a manual dose for and enter the amo...

Page 16: ...eriod of time it is worth calibrating pump heads to ensure accuracy To calibrate open the app and select the device you want to calibrate from the available devices list Tap the Settings icon located...

Page 17: ...dvised Tap on Add start and the pump will run for the time selected in the previous step Once the pump has stopped remove the outlet hose from the measuring cylinder and stand the measuring cylinder o...

Page 18: ...the settings page will open Select the pump name or the channel name you would like to change enter the new name and tap Save in the top right corner Update firmware If the firmware on the device is...

Page 19: ...ctory Settings Reset Use this function to factory reset the unit This will remove all programmed settings from the unit To reset the unit tap on Factory Settings Reset and select reset The unit will b...

Page 20: ...purchase D D The Aquarium Solution Ltd undertakes to repair or at our decision replace the defective part free of charge Our policy is one of continual technical improvement and we reserve the right...

Reviews: