1
Right stopper.
This machine is equipped with 2 side stoppers to prevent the carriage damaging the side limit
sensors.
2
Emergency laser sensor.
Designed to bring the machine into an emergency stop when intercepting the beam between the 2
sensors.
3
Touch Operating Panel.
Running on version 8. The manual comes separately.
4
PC control box’s main switch.
To turn ON/OFF the software side of the printer.
5
Maintenance cover.
Used when cleaning the printer and switching on the PC control box.
6
Automated capping station.
Moved up/down by a stepping motor. Use this capping station to cap the print heads always when not
printing. Bring down the capping station by pushing the left arrow in the touch panel. Raise the capping
station by pushing the home button in the touch panel.
7
Automated wiper unit.
If user executes Auto cleaning, this wiper will work automatically. To increase the wiper’s performance,
remove ink residue on wiper periodically.
8
Flushing stage.
The flushing unit is used to keep the print heads unclogged. Every time the carriage leaves the home
position for printing right to left, the heads flush a very small quantity of ink in order to keep the nozzles
always unclogged.
9
Magnetic LM block.
Do not use metal elements near this device. Clean the magnetic rail only with alcohol.
10
720dpi encoder strip.
Clean periodically the encoder strip with warm distilled water.