13. REMOVING THE TAKE-UP ROLL.
Removing the take-up roll is possible after pausing/cancelling the printing process.
Pause/Cancel the current job.
Switch off the take-up and the feeder. Use only MANUAL mode.
Make sure the front dancing bar is in the lowest position. If not, you may rotate the take-up roll
backwards to lower the front dancing bar. MANUAL BWD.
Once the front dancing bar is in the lowest point you may cut the media.
Release the latches at both sides of the take-up unit to remove the pneumatic shaft.
Remove the roll with the help of a roll lifter. If not, 2 persons is required for this operation.
Press the golden valve to release all the air inside the pneumatic tube.
Remove the pneumatic shaft from the media’s core.
Place the pneumatic shaft in the empty core orientating the printed side to the inside when winding.
With the help of an air compressor (only the air gun is provided) stick the gun to the golden valve and
apply compressed air until an approximate value of 5 bars is reached.
Lift the pneumatic shaft with the empty core fastened and place it carefully in the take-up unit.
Insert back the latches at both sides of the take-up unit to safely secure the pneumatic shaft.