12. FEED ADJUSTMENT.
Once the feeder and take-up units are correctly adjusted is time to start adjusting the feeding distance
more precisely to eliminate the banding effect.
Light band between passes. Means the feeding system has to feed
less distance while printing in order to eliminate the distance
between passes. To reduce the feeding compensation, in the touch
panel press the “VALUES” button and then proceed to press the
“minus” button as many times needed until no distance between
passes can be seen.
Dark band between passes. Means the feeding system has to feed
more distance while printing in order to eliminate the overlap
between passes. To increase the feeding compensation, in the
touch panel press the “VALUES” button and then press the “plus”
button as many times needed until no overlap between passes is
shown.
Note
To make the FEEDING COMPENSATION field effective, the PASSES field
must have the same number of passes as stated in the RIP software.
For example: if my RIP software is using an ICC profile of 4 passes, the
PASSES field must have an inputted value of 4. Otherwise the FEEDING
COMP. field will not work.
Note: even though the resample is ON printing at 8 passes but the RIP
software is using an ICC profile of 4 passes, the PASSES field must have
an inputted value of 4.