TITLE
OPERATOR MANUAL
PAGE
PRINTERS
TELEIOS HEXA
6
VERSION
2017JAN23/1
OUT OF
REVISED BY
MUNOZ, ANTONIO
support@dgen.com
63
FOR THE USER
d·gen International, Inc. - COMPANY PRIVATE (LEVEL 1)
NOT TO BE DISCLOSED TO UNAUTHORIZED PERSONS – PROHIBIDA SU DIVULGACIÓN A PERSONAS NO AUTORIZADAS
DO NOT REPRODUCE WITHOUT AUTHORIZATION – NO REPRODUCIR SIN AUTORIZACIÓN
8
Fixation unit’s electric cabinet.
This electrical panel contains hazardous components. Risk of Electrical Shock. It is used for
maintenance purposes. Only qualified technicians can access this electric panel. Normally closed
when using the printer.
9
Fixation’s take up unit.
Provides enough traction to move the media forward in a stable way. Comes in two configurations.
Two rubber rollers pulling the media towards a separate take-up reel or just one take-up shaft (like in
the picture).
10
Fixation unit.
Even the upper part of the fixation unit is protected against high temperatures, there is still a risk to
get burned if exposed to this heat for a long period of time. Please maintain this area clear from
foreign objects.
INTERIOR (CARRIAGE)
1
Solenoid valves.
The solenoid valve is opened if the LED is turned on. Having the solenoid valve opened allows free
circulation of negative air pressure between the vacuum pump and the head. Making the heads to
bleed for long purging is possible by closing the solenoid valve (LED switched off) right after the
purge button is pressed in the touch panel.
2
Carriage.
The carriage prints by moving left and right while firing ink. Periodical cleaning is required.
3
Carriage height adjustment lever.
This lever regulates the carriage height in 3 positions. Low, medium and high. Depending the
thickness of the media. There is a difference of 1 mm between positions.
4
Automated wiper unit.
If user executes Auto cleaning, this wiper will work automatically. To increase the wiper’s
performance, remove ink residue on wiper periodically.