Control elements
Position indicator
The position indication at the pushbutton of the drive symbolizes the position of the fitting.
The position of the marking is comparable with the position of a normal window handle.
Closed an
locked
Turning position
hinge on the right
Tilting position
Turning position
hinge on the left
Window
hinge on the right
(drive left-hand mounted)
Unlocking direction
Turning key
lights
(factory setting)
=
Window
hinge on the left
(drive right-hand mounted)
Turning key
does not light
=
Info key
lights
(factory setting)
Info key
does not light
=
=
Key illumination
switched on
Key illumination
switched off
The condition of the drive is
permanently displayed by
lighting of the corresponding
buttons.
The key Illumination turns off
automatically after 20 seconds.
>
5
Sec.
Basic Settings
The configuration mode for
setting the basic functions can
be started by pressing (> 5 Sec.)
the programming button. Press
the relevant button to change
the setting.
Exit the configuration mode by
pressing the programming
button again.
English
English
Position indicator (page 27)
Symbolizes the position of the fitting.
LED radio display
Every operation of the optional remote control will be
acknowledged by a flashing of the radio display.
CLOSE
Check the position of the rotary lock - it needs to be locked.
Briefly push to close the drive.
OPEN to the tilting position
Check the position of the rotary lock - it needs to be locked.
Briefly push to move the drive to the tilting position.
OPEN to the turning position
Push for 1 s and the drive moves the window to the turning
position for normal, manual opening.
Unlock the rotary lock and open the window manually.
Lock the rotary lock after closing the window.
Timer-controlled ventilation
Check the position of the rotary lock - it needs to be locked.
Briefly push once to move the drive to the opening position.
After a ventilation time of 10 minutes, it moves back to the
closed position. Pushing the key again extends the
ventilation time by 10 minutes each time:
Pushed once: ventilate for 10 min.
Pushed twice: ventilate for 20 min.
Pushed three times: ventilate for 30 min.
Automatic/interval ventilation
Check the position of the rotary lock - it needs to be locked.
Briefly pushing the automatic key activates automatic or
interval ventilation. If this is activated, the room will ventilated
in the parallel opening position for 10 minutes every hour.
Info
Briefly pushing the key will light up the symbols and display
the current modes for 20 s when darkened.
Programming key (page 27 and 30)
Summary of Contents for BDT-Advanced
Page 6: ...6 36 Deutsch BDT Advanced 99 828 08 1 0 12 19 8 9 50 mm Montage...
Page 7: ...7 36 Deutsch BDT Advanced 99 828 08 1 0 12 19 KLICK Montage...
Page 22: ...BDT Advanced 99 828 08 1 0 12 19 22 36 24 25 50 mm Mounting English...
Page 23: ...BDT Advanced 99 828 08 1 0 12 19 23 36 CLICK Mounting English...
Page 34: ...BDT Advanced 99 828 08 1 0 12 19 34 36...