background image

GVL 8301-K V2

GVL 8301-K V2

10/12

11/12

English

English

99.821.72 1.5/10/19

99.821.72 1.5/10/19

Electrical devices, accessories, batteries and packa-
ging  should  be  sorted  for  environmental-friendly 
recycling.  Do  not  dispose  electrical  devices  and 
batteries into household waste!
Only for EC countries:
According the European Guideline 2012/19/EU for 
waste  electrical  and  electronic  equipment  and  its 
implementation into national right, electrcal devices 
that are no longer usable must be collected separa-
tely  and  disposed  of  in  an  environmentally  correct 
manner.

Disposal

Declaration of Conformity

We  declare  under  our  sole  responsibility  that  the 
product  described  under  “Technical  Data”  is  in 
conformity with the following directives:

2014/30/EU, 2014/35/EU

Technical file at:
D+H Mechatronic AG, D-22949 Ammersbek

Dirk Dingfelder 

Maik Schmees

Member of the Board 

Authorized signatory, Technical Director

22.02.2016

Only if wind detector or rain detector available:

If the weather automatic is switched on via vent button LT 84-U-W 
(optional), the system will automatically close in case of wind or rain.
The system will not automatically open again, if wind or rain has 
stopped. Opening of the system for ventilation via vent button.
The weather automatic can be switched-off at vent button LT 84-U-W 
(optional), if gap ventilation is required in case of bad weather.
Gap ventilation is not possible in case of bad weather, if no vent 
button LT 84-U-W available.

Operation - Weather automatic

Automatic

on/off

LT 84-U-W

ST OP

ST OP

ST OP

Operation - Day-to-day ventilation

Open:

Close:

Stop:

Ventilation button required.

ST

OP

Connection examples

5

1

3

2

RTR 231

VRS 10

+24V

2

1

3

4

5

6

24 V DC
Window
Drive

P

P

S

LT 

84-

U-W

 

M1

GVL 8301-K V2

X1

1

2

Mot.b

5

Mot.b

8

Mot.b

1

Mot.a

4

Mot.a

7

Mot.a

3

Fail / 

TMS+

6

Fail / 

TMS+

9

Fail / 

TMS+

8

A

Z

7

–N

6

5

L

4

Az

Zz

3

+G

2

M2

M3

VCD 20x

VRS 10

+24V

2

1

3

4

5

6

2x 24 V DC
Window drives
on one window

P

P

S

LT 

84-

U-W

 

M1

GVL 8301-K V2

X1

1

2

Mot.b

5

Mot.b

8

Mot.b

1

Mot.a

4

Mot.a

7

Mot.a

3

Fail / 

TMS+

6

Fail / 

TMS+

9

Fail / 

TMS+

8

A

Z

7

–N

6

5

L

4

Az

Zz

3

+G

2

M2

M3

VCD 20x

LT 

84-

U

LT 

84-

U

* Connect lead directly when no automatic switch available. In this case the manual operation is out of function.

Ask your local D+H partner for further connection examples.

Automatic

on/off

Automatic

on/off

ST OP

ST OP

Maintenance and cleaning

Inspection  and  maintenance  has  to  be  carried  out 
according  to  D+H  maintenance  notes.  Only  original 
D+H spare parts may be used. Repair is to be carried 
out exclusively by D+H.
Wipe away debris or contamination with a dry, soft 
cloth.
Do not use cleaning agents or solvents.

Summary of Contents for GVL 8301-K V2

Page 1: ...99 821 72 1 5 10 19 GVL 8301 K V2 de Originalbetriebsanleitung Seite 2 Anschluss Seite 5 en Original instructions Page 7 Connection Page 10...

Page 2: ...die Innenmontage geeignet Bestimmungsgem eVerwendung Gruppe Fensterantriebe L ftungs taster Raumtemp Regler L ftungszentrale GVL 8301 K V2 Regenmelder Fremdansteuerung Anwendungsbeispiel optionale Fun...

Page 3: ...s 230 V Schutzkappe Netzanschluss Anschluss f r Zentralsteuerung Ersatzsicherung DIP Schalter S1 1 ON Die Antriebe fahren durch einmaliges Dr cken auf den L ftungstaster ZU 1 OFF Die Antriebe fahren n...

Page 4: ...m x Gesamtstrom 80 Gesamtstrom 0 5 A 240 400 640 1 A 120 200 320 m m m Typ 2x 1 5 mm 2x 2 5 mm 2x 4 mm Kabelverlegeplan Muster 230 V AC 50 Hz zu weiteren siehe Kabell ngen und Querschnitte Fensterant...

Page 5: ...2 M2 M3 VCD 20x VRS 10 24V 2 1 3 4 5 6 2x 24 V DC Fensterantriebe an einem Fenster P P S LT 84 U W M1 GVL 8301 K V2 X1 1 2 Mot b 5 Mot b 8 Mot b 1 Mot a 4 Mot a 7 Mot a 3 Fail TMS 6 Fail TMS 9 Fail TM...

Page 6: ...ten beschriebene Produkt mit den folgenden Richtlinien bereinstimmt 2014 30 1EU 2014 35 EU Technische Unterlagen bei D H MechatronicAG D 22949Ammersbek Dirk Dingfelder Maik Schmees Vorstand Prokurist...

Page 7: ...sized building objects For triggering of 24 V DC drives 1 ventilation group 1Atotal actuating current Expandable with D H accessories Only for indoor mounting WARNING Read all safety warnings instruct...

Page 8: ...1 ON Drives CLOSE up to final position by single pressing on vent button 1 OFF Drives are closing only so long as the vent button is pressed 2 ON Drives OPEN up to final position by single pressing on...

Page 9: ...tions window drive control panel vent button ca 1 2 m above upper edge firm flooring external control 4x 0 8 4x 0 8 2x 0 8 4x 0 8 rain sensor room temperature control Line lenghts and cross sections C...

Page 10: ...2 M2 M3 VCD 20x VRS 10 24V 2 1 3 4 5 6 2x 24 V DC Window drives on one window P P S LT 84 U W M1 GVL 8301 K V2 X1 1 2 Mot b 5 Mot b 8 Mot b 1 Mot a 4 Mot a 7 Mot a 3 Fail TMS 6 Fail TMS 9 Fail TMS 8...

Page 11: ...atory Technical Director 22 02 2016 Only if wind detector or rain detector available If the weather automatic is switched on via vent button LT 84 U W optional the system will automatically close in c...

Page 12: ...Germany 22949Ammersbek 49 239 Tel 40 605 65 49 Fax 40 605 65 254 E Mail info dh partner com www dh partner com 2016 D H Mechatronic AG Ammersbek Technische nderungen vorbehalten Rights to technical mo...

Reviews: