GVL 8301-K V2
GVL 8301-K V2
8/12
9/12
English
English
99.821.72 1.5/10/19
99.821.72 1.5/10/19
Type
GVL 8301-K V2
Nominal voltage
230 V AC, 50 Hz
Rated power
30 VA
Stand-by operating 4,3 W
Class of rating
short-time duty, 20%
Protection class
II
Ingress protection IP 66
Temperature range -5...+60°C
Output voltage
24 V DC, unstabilized
Output current
max. 1 A
Housing
plastic
Colour
light grey (~RAL 7035)
Dimensions
180 x 130 x 77 mm
Technical Data
View motherboard
Output voltage 24 V DC!
Do not run cables together with power lines!
In case of a cable with
ground wire
(e.g. green / yellow) this must
not be used
!
Wiring plan (Paragon)
230 V AC, 50 Hz
to further ones
see line lenghts and cross sections
window drive
control panel
vent button
ca. 1,2 m above
upper edge
firm flooring
external
control
4x 0,8 Ø
4x 0,8 Ø
2x 0,8 Ø
4x 0,8 Ø
rain sensor
room temperature
control
Line lenghts and cross sections
Cross section (mm²) =
cable lenght (m) x total current
80
total current
0.5 A
240
400
640
1 A
120
200
320
m
m
m
type
2x 1,5 mm²
2x 2,5 mm²
2x 4 mm²
230 V AC supply
Covering
Place enclosed protection cap
over supply terminal after mains
cable has been connected.
1 = ON
Drives
CLOSE
up to final position by
single pressing
on vent button.
1 = OFF
Drives are closing
only so long as
the vent button is
pressed
.
2 = ON
Drives
OPEN
up to final position by
single pressing
on vent button.
2 = OFF
Drives are opening
only so long as
the vent button is
pressed
.
Encoding of group
Following functions can be adjusted with
DIP
switch S1
on motherboard of control panel.
The delivery state of all DIP-switches is OFF.
Observe the safety notes which are
included to the drive!
fuse mains
drive connector
230 V protection cap
mains connector
connector for
central control
spare fuse
DIP switch S1
L
N
PE
230 V AC, 50 Hz