CDN36X User Manual
revision 1.30
Wiring
The CDN36X requires two connections – one to the DeviceNet network (male 5-pin micro
connector) and one to the target serial device (male DB9 connector). Follow all applicable
electrical codes in your area when mounting and wiring any electrical device.
All power is received from the DeviceNet network. The CDN36X draws up to 50mA from the
24VDC power supply. Select your DeviceNet cables and power supply so that it can provide
sufficient current for all networked devices at their peak operating power.
DeviceNet Interface
DRAIN
V+
V-
CAN_H
CAN_L
Male 5-Pin Micro Connector
PIN SIGNAL
COLOR
DESCRIPTION
1
DRAIN
NONE
Cable
shield
or
drain
wire.
2
V+
RED
DeviceNet
24VDC(+)
power.
3
V-
BLACK
DeviceNet
24VDC(-)
power.
4
CAN_H
WHITE
Communication
signal.
5
CAN_L
BLUE
Communication
signal.
Serial Channel Interface
1
9
5
6
2
3
7
8
4
Male DB9 Serial Connector
CDN366 (RS232)
PIN
SIGNAL DESCRIPTION
1
NC
No Connect. Do not connect any wires to NC pins.
2
RXD
Receive Data. RS232 input signal.
3
TXD
Transmit Data. RS232 output signal.
4 NC
No
Connect.
5
GND
Ground. Common for RS232 signals.
6 NC
No
Connect.
7
RTS
Request To Send. RS232 output signal.
8
CTS
Clear To Send. RS232 input signal.
9 NC
No
Connect.
MKS Instruments, Inc.
D.I.P. Products Group
6