12
3. Route a straight, uncrimped Ethernet cable (8-wire, 24 AWG) through
both the top nut and the waterproof seal.
NOTE:
The 8-wire cable should be shielded.
4. Insert and crimp the RJ-45 connector. Refer to Appendix B for
instructions on preparing the RJ-45 cable connector.
5. Connect the Ethernet cable to the Outdoor unit RJ-45 connector.
6. Replace the waterproof seal and then the top nut. Make sure that the
external jack of the cable is well inside the waterproof seal to guarantee a
good seal.
7. Route the cable to the location selected for the Indoor unit.
2.5 Installing the Indoor Unit
Route the Indoor-to-Outdoor cable into the building so that it conveniently reaches
the indoor unit while avoiding interference sources. It is recommended that the
cable be a little longer then necessary. The cable is supplied open ended so it can be
conveniently threaded as shown into the building.
1. Remove the wall-mounting bracket clipped to the back of the indoor unit
and mount it on a wall as shown in Figure 6. Mount the indoor unit on
the mounting bracket.
2. Assemble an RJ-45 connector with a protective cover on the indoor side
of the Indoor-to-Outdoor cable. Refer to Appendix B for instructions on
preparing the RJ-45 cable connector.
3. Connect the Indoor-to-Outdoor cable to the Radio connector, located on
the top panel of the indoor unit shown in Figure 8 on page 14. The
Indoor-to-Outdoor cable should be connected to the unit before the unit
is connected to the mains power.
Summary of Contents for AirPremier DWL-1800
Page 15: ...10 Figure 3 Holes Grooves Screw Holes ...
Page 77: ...72 ...