DGS-3048 Gigabit Ethernet Switch Manual
cannot be the same port.
System Log Settings
The Switch can send Syslog messages to up to four designated servers using the System Log Server. In the
Administration
folder, click
System Log Settings
, to view the window shown below.
Figure 7- 9. System Log Servers Window
The parameters configured for adding and editing System Log Server settings are the same. To add a new Syslog Server,
click the
Add
button. To modify a current entry, click the hyperlinked number of the server in the Index field. Both actions
will result in the same window to configure. See the table below for a description of the parameters in the following window.
Figure 7- 10. System Log Server – Add Window
The following parameters can be set:
Parameter
Description
Index
Syslog server settings index.
Server IP
The IP address of the Syslog server.
Severity
This drop-down menu allows you to select the level of messages that will be sent. The
options are
Warning
,
Informational
, and
ALL
.
Facility
Some of the operating system daemons and processes have been assigned Facility
values. Processes and daemons that have not been explicitly assigned a Facility may
use any of the "local use" facilities or they may use the "user-level" Facility. Those
Facilities that have been designated are shown in the following. Bold font denotes the
facility values that the Switch currently implements.
Numerical Facility
Code
29