D-Link NetDefend Firewall
3
E
NG
LIS
H
Installing Equipment
DFL-800/DFL-860 Default Interface Settings
Table 3. DFL-800/DFL-860 Default Interface
Assignment
Note:
For security, D-Link NetDefend Firewalls
only allow Web GUI access from the LAN1 port by
default. That means the Web GUI access is only
allowed on LAN port labeled 1 of front plate by
default for DFL-800/DFL-860.
Installing and Connection
This section describes how to install a DFL-800/
DFL-860 device in a standard 11-inch equipment
rack and how to connect network and power
cables to the device.
Before You Begin
Observe the following precautions to help prevent
faults, equipment failures and injuries:
Before installation, always disconnect the
-
power supply.
Ensure that the room in which you operate the
-
device has adequate air circulation and that
the room temperature does not exceed 40˚C
(104˚F).
Allow 1 meter (3 feet) of clear space from the
-
front and back of the device.
Do not place the device in an equipment rack
-
frame that blocks the air vents on the sides of
the chassis. Ensure that enclosed racks have
fans and vented sides.
Correct any of the following hazardous
-
conditions before any installation: moist or wet
floors, leaks, ungrounded/frayed power cables,
or missing safety grounds.
You can mount the DFL-800/DFL-860 device into
a standard 11-inch equipment rack. To install a
DFL-800/DFL-860 device into a rack:
1. Attach the mounting brackets to each side of
the chassis as shown in Figure 3 and secure
them with the provided screws.
Connecting Power and Turning On/Off
The AC Power cord shipped with the device
connects the device to earth ground when
plugged an AC grounding-type power outlet. The
device must be connected to earth ground during
normal operation.
To connect power to the device, plug one end of
the AC power core into the AC power appliance
inlet on the back panel of the device. Plug the
other end into an AC power source.
Note:
D-Link recommends the use of a surge
protector with your power connection.
Port
Name
Interface
Type
IP Address
Web-Based
Mgmt
WAN1 WAN1
DHCP
Client
0.0.0.0/0
Disabled
WAN2 WAN2 Static IP
192.168.120.254/24 Disabled
DMZ
DMZ
Static IP
172.17.100.254/24
Disabled
Ports:
1~7
LAN
Static IP
192.168.1.1/24
Enabled
Figure 3. Attaching Rack Mount Brackets
2. Use the screws provided with the equipment rack
to mount the device in the rack.
Figure 4. Installation Using a Standard-sized
Equipment Rack