DGS-1510 Series Gigabit Ethernet SmartPro Switch Web UI Reference Guide
46
To view the following window, click
Management > RMON > RMON Alarm Settings
, as shown below:
Figure 4-18 RMON Alarm Settings window
The fields that can be configured are described below:
Parameter
Description
Index
Enter the alarm index. The range is from 1 to 65535.
Interval
Enter the interval in seconds for the sampling of the variable and
checking against the threshold. The valid range is from 1 to
2147483648 seconds.
Variable
Enter the object identifier of the variable to be sampled.
Type
Select the monitoring type. Options to choose from are
Absolute
and
Delta
.
Rising Threshold
Enter the rising threshold value between 0 and 2147483647.
Falling Threshold
Enter the falling threshold value between 0 and 2147483647.
Rising Event Number
Enter the index of the event entry that is used to notify the rising
threshold crossing event. The valid range is from 1 to 65535. If not
specified, no action is taken while crossing the ringing threshold.
Falling Event Number
Enter the index of the event entry that is used to notify the falling
threshold crossing event. The valid range is from 1 to 65535. If not
specified, no action is taken while crossing the falling threshold.
Owner
Enter the owner string up to 127 characters.
Click the
Add
button to add a new entry based on the information entered.
Click the
Delete
button to remove the specified entry.
Enter a page number and click the
Go
button to navigate to a specific page when multiple pages exist.
RMON Event Settings