background image

- 40 -

program will continue automatically. When finished, Windows will
prompt you to restart your computer. Click 

Yes 

to continue.

Summary of Contents for DIM-128 - 56 Kbps Fax

Page 1: ...ISDN TA 56k FAX MODEM PC Card User Manual ...

Page 2: ...or above At least 30MB free hard disk space At least 16MB RAM PCMCIA Type II III slot PCMCIA Card Services and Socket Services v 2 1 or higher pre installed Windows 95 98 2000 or Windows NT pre installed Specifications Standard PCMCIA 2 1 JEIDA 4 1 compliant ISDN standards Basic Rate Access 2B D U Interface Compliant with ANSI TI 601 S T Interface Compliant with ITU T I 430 D channel ITU T Q 921 Q...

Page 3: ... Switch Compatibility National ISDN 1 NI 1 AT T 5ESS Custom Northen Telecom DMS 100 Custom DSS1 Euro ISDN INS Net 64 Application Program Interface Supported VCOMM WinISDN CAPI 2 0 NDIS WAN Operating System Supported Windows 95 and OSR2 Windows 98 Windows 2000 Windows NT 4 0 Physical Specifications RJ 45 ISDN line interface Dimension 85 6 x 54 x 5 mm PCMCIA Type II ...

Page 4: ...3 Parts Names 15 pin PC Card Connector Analog Fax Modem DAA Connccet to PSTN Telephone Line 15 pin PC Card Connector ISDN Network Connection Cable Ear piece ISDN Phone Kit Microphone Connect to ISDN Line ...

Page 5: ...ble will not be installed in the wrong place The modem cable is on the right while the ISDN cable is on the left Push evenly and steadily until the units click 3 Connect the ISDN line to the opposite end of the ISDN Network Connection Cable Note If your NT1 box does not have 100 ohm resistor then the 100Ω Ω Ω Ω terminator resistor optional is required and should be used as a connector to connect t...

Page 6: ...ile setting up and move to the corresponding section for details VCOMM Port Hyper Terminal CAPI 2 0 RVS COM NDIS Port ISDN Low Driver DUN CAPI NDIS VCOMM Interface Center Driver Level Driver PPP V 120 V 110 PPP V 110 X 75 V 120 Modem Eurofile Transfer G3 FAX over ISDN PPP Windows 95 98 2000 The blocked area indicate that after when setup exe has been executed see section titled Installing Device D...

Page 7: ...tion PPP The blocked area indicate that after when setup exe has been executed see section titled Installing Device Driver the Phone Dialer CAPI mode and NDIS were also installed You may then use Phone Dialer or the functions with NDIS mode directly For CAPI mode however it is required to install RVS COM Center beforehand to enable the functions with CAPI ...

Page 8: ... Win9x when in Windows 95 98 or Win2000 for Windows 2000 4 Double click Setup exe The installation program will proceed automatically Follow the on screen instruction While for installation under Windows 2000 remember to close the following window to continue 5 When finished click the Finish button and you will be asked to restart your computer Before your computer is reset insert the PCMCIA card ...

Page 9: ...section titled the appropriate API for your need for installation VCOMM Mode COM port is commonly used for connecting to the external ISDN devices With the VCOMM COM port emulation the ISDN multifunction PC Card works exactly like an ISDN TA Terminal Adapter external box which can run with traditional terminal program packages such as Windows 95 Hyper Terminal Procom Plus for Windows Telix pcAnywh...

Page 10: ...lly the country and area codes are not required and should be disabled 6 From the Dial Up Networking window right click your newly created connection Select Properties On the General tab cancel the selection of Use area code and Dialing Properties and click OK 7 From the Start menu select Programs Select Configuration Utility Click Config A dialogue box will prompt you to change the settings to fi...

Page 11: ...llows Area Switch Type Canada United States Northern Telecom NI 1 Japan INS Net 64 Taiwan DSS1 ETSI Europe DSS1 ETSI 9 Enter in the ISDN phone numbers and the Service Profile Identifier Number SPID will be supplied by your local ISDN telephone company NOTE With the INS Net 64 DSS1 ETSI switch types there are no SPID s to be entered 10 Now you are ready to connect your ISDN Network Connection Cable...

Page 12: ...am Select Configuration Utility Execute CONFIG 2 Open General tab Click MP Enabled in PPP Setting 3 Apply the other settings BOD Enabled and Second Phone No if available Making V 110 Connections 1 Execute Config in Configuration Utility 2 Select the COM Port Setting tab Select V 110 for B Channel protocol in 1st COM port setting 3 Make sure Dial Up Networking is well installed 4 Double click Make ...

Page 13: ...nection 5 Name the new connection appropriately For example V 120 6 Select Intelligent ISDN MODEM modem in the Select a device box 7 Click Configure button and give the appropriate settings Ignore the Maximum speed setting but you are still recommended to set to the speed at higher than 64000 bps such as 115200 or higher Click Next 8 Enter the ISDN phone number of the remote party that you want to...

Page 14: ...he Fax Modem over ISDN function lets you seamlessly talk to the analog fax modem devices at the remote sites over ISDN line 1 Go to Configuration Utility execute Config 2 Open COM port setting Select Modem over B channel in 1st COM port setting Click Apply and OK 3 Open Switch type Choose appropriate Voice Encoding scheme for your location 4 Run HyperTerminal Select Intelligent ISDN MODEM modem 5 ...

Page 15: ...tter for you try either one 4 Enter Tools in configuration utility Click Phone Dialer to make voice calls 5 Enter the remote party phone number by pressing the number key pad on the screen or type the phone number directly in the blank space of Number to Dial then press Dial button to dial out the phone number Give the extension number and press Dial Ext button if the remote party is an auto atten...

Page 16: ... ISDN MODEM PC Card The function makes you connect to the remote party through normal analog telephone line PSTN if you could not get ISDN line at your places home office hotel or on the road You can use fax or modem for your applications 1 Switch the ISDN S T or U interface network connection cable to analog fax modem DAA network connection cable and hook up the analog telephone line 2 Enter Conf...

Page 17: ...plications in CAPI mode the RVS COM CommCenter is required to be executed If the RVS COM is not yet installed on your computer perform the following procedures Installing RVS COM Lite 1 Insert the RVS COM compact disc into your CD ROM drive Press Yes when the opening screen appears 2 Follow the on screen instruction to proceed 3 When finished the installation program will restart your computer Whe...

Page 18: ...ll installed you may check by going to the Start menu Settings Control Panel Modems to see if RVS ISDN Internet PPP exists in there as illustrated below Making PPP connections 1 Execute RVSCommCenter 2 Click Make new Connection in the Dial Up Networking folder Name the new connection appropriately for example RVS_PPP Select RVS ISDN Internet PPP ...

Page 19: ...ow you are ready for Internet access through CAPI Making Multilink PPP Connections There are two ways to setup the ISDN PC Card for Multilink PPP MP or MLP connections through CAPI mode Method 1 1 Execute RVSCommCenter 2 Complete the PPP connection setup in the previous section 3 Execute Config Start Programs Configuration Utility ...

Page 20: ...t access Method 2 1 Execute RVSCommCenter Click the Service tab 2 When the above dialog box appear check 2nd COM port and click OK 3 Go to My computer Select Control Panel Double click Modem Click Add 4 Select Other Modem Click Next 5 Select Don t detect my modem I will select it from a list Click Next 6 Select RVS Datentechnik RVS ISDN Internet PPP Click Next ...

Page 21: ...elect the RVS COM ISDN port that you just added Click Next 8 Click Finish 9 Now you can see RVS ISDN Internet PPP 2 in the modem list in Control Panel Æ Modem 10 Enter Dial Up Networking folder in My Computer ...

Page 22: ...o finish 13 Right click the new connection in Dial Up Network Click Property 14 Click the Multilink tab Check Use additional device Click Add Select RVS ISDN Internet PPP 2 Click OK to complete the Multilink PPP settings Making V 110 Connections 1 Execute CommCenter And make sure all the settings are well and correctly configured 2 Go to My Computer Make sure Dial Up Networking DUN is well install...

Page 23: ...sh to complete the setting Making V 120 Connections 1 Execute CommCenter And make sure all the settings are well and correctly configured 2 Double click Make New Connection 3 Name the new connection appropriately For example V 120 4 Select RVS ISDN V 120 in the Select a device box 5 Click Configure button and give the appropriate settings Ignore the Maximum speed setting you are recommended to set...

Page 24: ...dem for data transfer For servers which support X 75 T 70NL protocol you have to choose RVS ISDN X 75 T 70NL in the above setup steps EuroFile Transfer Applications 1 Start RVS CommCenter If your are to act as an answering party host mode check Accept calls otherwise disselect this box to act as the calling party Check Eurofile transfer 2 Start the RVS TransferMaster The New Connection dialog appe...

Page 25: ...ect To dialog box Click Connect 5 The connection will be established and you will then see the folder that the other party has made available to you for access Use Drag Drop or the Clipboard Copy Paste to transfer files between Explorer windows or the Desktop on your PC and the folder on the other party s PC and vice versa Access any sub folders on the remote PC by double clicking on the symbols T...

Page 26: ... function refer to Softmodem and SoftwareFax tab Click Apply and OK 4 Run Config in Configuration Utility 5 Enter General tab 6 Click Modem over ISDN B Channel in Modem Setting for RVS COM 7 Select Answered by Modem in Incoming Call Answering the incoming analog calls will be answered by the built in modem 8 Click Apply and OK 9 Open Switch type Choose appropriate Voice Encoding scheme for your lo...

Page 27: ... details Making Modem over PSTN Connections The Modem over PSTN is also possible in CAPI through working together with RVS COM Lite software Note The Fax over PSTN function does not work in this case 1 Run RVS COM CommCenter 2 Disable the Use Softmodem and Use SoftwareFax to send receive fax function refer to Softmodem and SoftwareFax tab Click Apply and OK 3 Connect the analog fax modem DAA netwo...

Page 28: ...r other Microsoft DUN based application programs make new connections through Dial Up Networking to connect to the remote parties Making G3 Fax over ISDN 1 Start CommCenter 2 Open the SoftwareFax tab Select Use SoftwareFax to receive fax to receive a fax Or select Use SoftwareFax to send fax to send a fax 3 Open ISDN tab Select appropriate ISDN voice encoding scheme for your location Generally you...

Page 29: ... 28 4 Open the Service tab Select Accept calls Select Fax Click OK Sending a fax 1 Start Create New Fax in the RVS COM group programs Click OK ...

Page 30: ...cessary information When all set RVS will send out the fax for you automatically Receiving a fax 1 Wait for incoming fax calls 2 You can go to Inbox to read the incoming fax Voice Applications The voice applications included are 1 Digital answering machine ...

Page 31: ...n Digital Answering Machine 1 Start RVSCommCenter 2 Open the Service tab Check Accept calls Check Answerphone 3 Open the ISDN tab select the appropriate ISDN voice coding scheme for your location A law is usually used in European countries and Mu law for North America 4 Make sure all the other settings in RVS CommCenter are correctly configured Click Ok 5 Run Config in Configuration Utility 6 Open...

Page 32: ...ISDN Phone 1 Start RVS COM CommCenter 2 Open the Service tab Clear the selections of the Accept calls and the Answerphone check box 3 Open the ISDN tab select the appropriate ISDN voice coding scheme for your location A law is generally used in European countries and Mu law for North America 4 Make sure all the other settings in CommCenter are correctly configured Click OK ...

Page 33: ...hone in RVS COM Lite program group 8 Click Answerphone function bar to the OFF state for the ON state is for Answering machine services 9 Connect the microphone and speakerphone to the audio interface s on your laptop When the calls come in the RVS Phone will appear automatically Click Accept button to pick up the calls When finished click Hang Up to end the connections ...

Page 34: ... Network adapters in Hardware types list Click Next 5 Select Intelligent in Manufacturers and Intelligent ISDN MODEM Net in Models Click OK 6 Click Finish 7 Click Next 8 Select the appropriate ISDN Switch protocol Click Next The settings will be used for Dial Up Networking utility through NDIS WAN application program interface 9 Enter the ISDN phone number s Click Next 10 Click Finish When system ...

Page 35: ...your ISP that you want to call 6 Click Next and click Finish to complete the setting 7 Now you can use the Internet application software for example Microsoft Internet Explorer or Netscape Communicator to connect to ISP Making Multilink PPP Connections 1 When the PPP connection settings method 2 in the previous section is completed right click the NDIS connection icon in DUN and select Properties ...

Page 36: ...dditional device name and the secondary phone number if available for making Multi Link PPP connections 3 Click OK to finish the Multi Link PPP settings 4 Open the Server Types folder and complete all the TCP IP settings accordingly refer to the information provided by your Internet Service Provider ISP Click OK ...

Page 37: ... 36 5 Now you can use the Internet application software for example Microsoft Internet Explorer or Netscape Communicator to connect to ISP with Multilink PPP mode ...

Page 38: ...o to Control Panel You may go to the Start menu select Setting to open the Control Panel folder 2 Select Network A Network dialog box will appear as illustrated below 3 Select Adapter tab Click Add 4 The following dialog box will appear Click Have Disk and click OK to continue ...

Page 39: ...When the Select OEM Option dialog box appear click OK to continue 7 The following dialog box will prompt you to change the I O and IRQ settings You may refer to the Hardware Detection to know the available addresses to avoid any conflicts with your system Go to the Start menu Click Programs Select Configuration Utility Open Hardware Detection 8 Press OK to continue The installation program will pr...

Page 40: ...Click Properties The following figure will appear 12 Select Add When the Add RAS Device dialog box appears select ISDN1 ISDN_TA and click OK Press Add again to add ISDN2 ISDN_TA When completed press Continue You will be prompted to the Network dialog box again Click Close to continue The installation ...

Page 41: ... 40 program will continue automatically When finished Windows will prompt you to restart your computer Click Yes to continue ...

Page 42: ...ion NDIS Mode 1 Insert the application software disk or compact disc into your computer 2 Go to the Start menu Click Run 3 If you are using compact disc to install the application software type in the CD ROM drive letter followed by winnt ntap setup Or if you are using disk type in a setup The Configuration Utility installation program will proceed automatically 4 Follow the on screen instruction ...

Page 43: ...Networking 2 Click New to name the phonebook Enter the name properly 3 Shift to the next tab to enter the required data as illustrated below 4 When finished click OK Select Dial to continue 5 When the Connect to ISDN dialogue appears you are on the Internet ...

Page 44: ...t the COM port that is identical to the COM port assignment in Windows Port Click Next 6 Click Finish 7 Now you will see RVS ISDN Internet PPP in the modem properties list 8 Click Close 9 Click Yes when Modem Setup window pops up 10 Click Add in Remote Access Setup dialog window 11 Select COM RVS ISDN Internet PPP in RAS device list Click OK 12 Click Continue Then re start Windows NT 13 Run RVS CO...

Page 45: ...ort that you just assigned at step 2 Click Next 9 Click Finish 10 Now you will see RVS ISDN Internet PPP 2 in the modem properties listed in Control Panel Æ Modems Click Close 11 Click Yes when Modem Setup window appears 12 Click Add in Remote Access Setup dialog box 13 Select COM RVS ISDN Internet PPP 2 in RAS device list Click OK 14 Click Continue Then re start Windows NT 15 Run RVS COM CommCent...

Page 46: ...opriate Voice Encoding scheme The setting should be consistent with RVS COM in step 3 Now you are ready to use the RVS COM s Softmodem function Refer to the RVS COM on line documentation for application details Making G3 Fax over ISDN 1 Start CommCenter 2 Open the SoftwareFax tab Select Use SoftwareFax to receive fax to receive a fax Or select Use SoftwareFax to send fax to send a fax 3 Open ISDN ...

Page 47: ...S device successfully remove the non used device name then add RVS ISDN Modem analog 13 Click Continue Then re start Windows NT 14 Run RVS COM CommCenter 15 Go to Control Panel Æ Network Æ Adapter Click Properties 16 Select Modem over B chan in Modem choice Click OK Also specify the Analog encoder for your location For example select Mu law for N America A law for European countries 17 Double clic...

Page 48: ...ccess Setup dialog window 13 Select COM RVS ISDN Modem analog in RAS device list Click OK If you could not add the RAS device successfully remove the non used device name then add RVS ISDN Modem analog 14 Click Continue Then restart Windows NT 15 Run RVS COM CommCenter 16 Go to Control Panel Æ Network Æ Adapter Click Properties Select Modem over PSTN in Modem choice Click OK 17 Double click Dial U...

Page 49: ...he detailed ISDN AT command definition Using ISDN AT Commands As mentioned above you can use ISDN TA PC card through AT besides except through communication software carefully every time because they can cause your software to loose its ability to control the modem When you do find any AT command causes ISDN TA maul function turn the computer off and then on That will reset most of the AT command ...

Page 50: ...refer to AT Wn commands for details otherwise the changes will get lost when you restart or shut down the computer Type AT F Wn Enter if you get lost in the AT command and want to go back to the factory default settings Exception Do not proceed the following commands with an AT prefix or end it by pressing Enter Escape sequence The escape sequence allows the modem to exit data mode and enter on li...

Page 51: ...e then the ATB will be set to default speed 38400 ATD number Make ISDN data calls e g ATD5551000 ATDM number Make modem calls over ISDN line e g ATDM5551000 ATDT number Dial out the ISDN phone number e g ATDT5551000 ATDV number Make ISDN Phone voice calls e g ATDV5551000 ATDSn Dial out the pre stored phone number n 0 1 2 Refer to AT Zn number command for phone number storage ATDL Re dial the last ...

Page 52: ...dio speech n 3 Enable 3 1K Hz audio AT Z n B channel protocol selection n 05 V 120 n 06 V 110 n 09 Async to Sync PPP conversion Note The commands are used to change certain fundamental configuration parameters which are changed very infrequently often only once at installation Using these commands during normal operation with the telephone line connected to the Terminal Adapter TA can cause unpred...

Page 53: ... 52 APPENDIX B BASIC AT COMMAND SET Refer to the file named MDMCMD TXT that came together with this user manual for the Fax Modem AT command details ...

Reviews: