146
Appendix C Performing Advanced Diagnostics
Appendix D Replacing and Upgrading FRUs
This appendix describes how to replace or upgrade the Field Replaceable Units (FRUs) in your
xStack Storage Array. FRUs that can be replaced or upgraded include:
Battery Pack
System and buffer memory
SATA drives
Fans
Uninterruptible power supplies
D.1 Installing the Battery Pack
The xStack Storage Array accommodates a 4-cell or 6-cell shrink-wrapped battery pack.
Because write-back caching is always enabled, we recommend you have a battery to back up
the buffer cache contents.
To install a battery in your xStack Storage SAN Array, follow these steps:
1.
Hold the battery as shown to align the fastener pad. Make sure the battery cable and
connector is located nearest to the battery socket J35 on the controller (see Figure D-1 ).
Figure D-1 Aligning the Battery