xStack Storage User’s Guide
63
If you select an unacceptable configuration, the
Finish
button remains gray
and unavailable until you correct the configuration. Examples are an odd
number of drives for a mirrored stripe configuration, 1 or 2 drives for a
parity volume, and 1 drive for a Mirror configuration.
If you specify a volume larger than the selected drives can support, an error
message appears after you click the
Finish
button. Click
OK
to remove the
message, then repeat this procedure and specify a smaller volume.
Table 5-6 Manual Create Volume Wizard - Select Volume Type to Create Screen Settings
Setting
Description
Name
Enter the name of the volume you are creating.
Size
Enter the size of the volume you are creating ((MB, GB, TB, etc.). Do not type a decimal
point. Use the drop-down box to select the volume capacity:
Configuration
Select the desired organization (JBOD, Stripe, etc.). Table 5-2 lists the volume
organizations.
Chunk Size
Select the size (32K, 64K, etc.) of each chunk from one of the commonly used chunk
sizes. If you selected
JBOD
or
Mirror
as your configuration setting, the
Chunk Size
setting is gray and unavailable.
After a volume is created, you can use the
Advanced
tab to write-protect
the volume and suppress Synch Cache commands from the host (see
5.4.1.4).
5.4.1.2
Expanding a Volume
If you want to add capacity to a volume, expand the volume to increase its physical capacity.
1.
In the
Logical Resources
tab, click the volume whose capacity you want to expand.
2.
On the
Storage
menu, click
Expand Volume
. The Expand Volume dialog box appears (see
Figure 5-15).
Summary of Contents for DSN-3400-10 - xStack Storage Area Network Array Hard...
Page 10: ...x Contents...
Page 20: ...20 Chapter 2 Identifying Hardware Components Figure 2 6 Press Lever Inwards Until it Locks...
Page 36: ......
Page 44: ...44 Chapter 4 Starting the xStack Storage Array for the First Time...
Page 103: ...xStack Storage User s Guide 103...
Page 117: ...xStack Storage User s Guide 117 Figure 6 12 Viewing SMART Attributes...
Page 160: ...160 Appendix D Replacing and Upgrading FRUs...
Page 164: ...164 Appendix F Hardware Enclosures...