xStack Storage User’s Guide
81
8.
The left box lists all the iSCSI initiators you have defined. Click the iSCSI initiator(s) in this
list that are allowed to access the volumes through the target network portals whose IP
addresses you
selected
in the previous screen.
9.
Click Add to move the selected iSCSI initiator(s) to the right box.
If you want to remove an iSCSI initiator from the right box, click the iSCSI
initiator in the right box and click
Remove
to return the iSCSI initiator to the
left box.
10.
Click
Next
. The Volume Access Right screen appears (see Figure 5-32).
Figure 5-32. Create iSCSI Node Wizard – Volume Access Right Screen
11.
The left box lists all the volumes you have created. Click a volume in this list, then click
Add
to move the selected volume to the right box. Note that all volumes currently can have only
Read/Write access, which is the default.
You can select more than one volume in the left box:
To select contiguous volumes, click the first one; then hold down the Shift
key and click the last volume.
To select noncontiguous volumes, click the first volume; then hold down
the Ctrl key and click each additional volume you want to select.
To deselect a volume, hold down the Ctrl key and click the volume.
Summary of Contents for DSN-3400-10 - xStack Storage Area Network Array Hard...
Page 10: ...x Contents...
Page 20: ...20 Chapter 2 Identifying Hardware Components Figure 2 6 Press Lever Inwards Until it Locks...
Page 36: ......
Page 44: ...44 Chapter 4 Starting the xStack Storage Array for the First Time...
Page 103: ...xStack Storage User s Guide 103...
Page 117: ...xStack Storage User s Guide 117 Figure 6 12 Viewing SMART Attributes...
Page 160: ...160 Appendix D Replacing and Upgrading FRUs...
Page 164: ...164 Appendix F Hardware Enclosures...