DXS-3600 Series Layer 3 Managed 10Gigabit Ethernet Switch CLI Reference Guide
757
This command is used to configure the RSPAN VLAN and destination port for an RSPAN source session.
Use the
no
form of the command to remove the configuration of the RSPAN VLAN.
monitor session SESSION-NUMBER destination remote vlan VLAN-ID interface INTERFACE-ID
monitor session SESSION-NUMBER destination remote vlan access-list ACCESS-LIST-NAME
replace vlan VLAN-ID
no monitor session SESSION-NUMBER destination remote vlan [access-list ACCESS-LIST-
NAME]
Parameters
SESSION-NUMBER
Specifies the session number for the monitor session. The valid range
is 1 to 4.
VLAN-ID
Specifies the RSPAN VLAN used to tunnel the monitored packets to
the remote site. The valid range is 2 to 4094.
interface INTERFACE-ID
Specifies the interface to transmit the monitored packets to the remote
site.
access-list ACCESS-LIST-
NAME
Specifies the flow used to perform egress per-flow RSPAN VLAN
replacement. Even if the access list does not exist, the flow can still be
configured.
replace vlan VLAN-ID
Specifies the VLAN ID used to replace the RSPAN VLAN ID for the
matched flow of packets transmitted out from the destination port on a
RSPAN source switch. The valid range is from 1 to 4094.
Default
None.
Command Mode
Global Configuration Mode.
Command Default Level
Level: 12.
Usage Guideline
Use this command on the source switch of an RSPAN session.
The
monitor session destination remote vlan
command configures the destination port used to
transmit the monitor packets and the RSPAN VLAN used to tag the monitored packets to the remote site.
For each session, only one destination interface can be configured. The destination port does not need to
be the member port of the RSPAN VLAN. The destination port can be either a physical port or a port
channel.
Each session should be configured with a unique RSPAN VLAN. The user cannot specify an interface for
the command to transmit the monitored packets for multiple RSPAN sessions.
A flow can be specified by specifying an access list name to match the packets monitored by the session.
If matched, the RSPAN VLAN ID will be used to tunnel these packets and will be replaced by the replace
VLAN ID.
Use the
monitor session source interface
command to configure the source ports whose packets will
be monitored.
Use the
remote-span
command in the VLAN configuration mode to specify a VLAN as an RSPAN VLAN.
The monitored packet will be tunneled over the trunk member port of the RSPAN VLAN in the subsequent
switches.
Example
Summary of Contents for DXS-3600 Series
Page 1: ......
Page 423: ...DXS 3600 Series Layer 3 Managed 10Gigabit Ethernet Switch CLI Reference Guide 418 ...
Page 548: ...DXS 3600 Series Layer 3 Managed 10Gigabit Ethernet Switch CLI Reference Guide 543 ...
Page 673: ...DXS 3600 Series Layer 3 Managed 10Gigabit Ethernet Switch CLI Reference Guide 668 ...
Page 712: ...DXS 3600 Series Layer 3 Managed 10Gigabit Ethernet Switch CLI Reference Guide 707 Switch ...
Page 845: ...DXS 3600 Series Layer 3 Managed 10Gigabit Ethernet Switch CLI Reference Guide 840 ...
Page 884: ...DXS 3600 Series Layer 3 Managed 10Gigabit Ethernet Switch CLI Reference Guide 879 ...
Page 1152: ...DXS 3600 Series Layer 3 Managed 10Gigabit Ethernet Switch CLI Reference Guide 1147 ...