143
Chapter 5: Troubleshooting
5.1 WebPAM PROe system event log
Controller
Corrective Action
The controller parameter(s)
changed by user
The user successfully changed controller
settings.
The controller has new
crash information
Check the event logs.
Controller temperature is
above the warning
threshold
The controller is overheating. Check for
airflow around and through the controller,
and verify that all fans are working. Replace
fans as needed.
Controller temperature is
above the critical threshold
The controller is seriously overheating.
Check for airflow around and through the
controller, and verify that all fans are
working. Replace fans as needed.
Controller temperature is
within the warning threshold
Normal.
Disk Array
Corrective Action
New disk array has been
created
Result of settings or user action. Normal.
Disk array has been deleted Result of settings or user action. Normal.
Disk array has been added
Result of settings or user action. Normal.
Disk array has been
removed
The physical drives of the disk array were
removed from the enclosure.
Disk array settings have
been changed
The user successfully disk array settings.
Enclosure
Corrective Action
Enclosure temperature is
above the warning
threshold
The chassis is overheating. Check for
airflow around and through the chassis, and
verify that all fans are working. Replace fans
as needed.
Enclosure temperature is
above the critical threshold
The chassis is seriously overheating. Check
for airflow around and through the chassis,
and verify that all fans are working. Replace
fans as needed.
Enclosure temperature is
within the normal range
Normal.