xStack
®
DGS-3120 Series Layer 3 Managed Gigabit Ethernet Switch CLI Reference Guide
361
high_alarm
- (Optional) Specify the high threshold for the alarm. When the operating
parameter rises above this value, the action associated with the alarm is taken.
<voltage>
- Enter the high threshold alarm value used here.
low_alarm
- (Optional) Specify the low threshold for the alarm. When the operating parameter
falls below this value, the action associated with the alarm is taken.
<voltage>
- Enter the low threshold alarm value used here.
high_warning
- (Optional) Specify the high threshold for the warning. When the operating
parameter rises above this value, the action associated with the warning is taken.
<voltage>
- Enter the high threshold warning value here.
low_warning
- (Optional) Specify the low threshold for the warning. When the operating
parameter falls below this value, the action associated with the warning is taken.
<voltage>
- Enter the low threshold warning value here.
bias_current_threshold
- Specify the threshold of the optic module’s bias current.
high_alarm
- (Optional) Specify the high threshold for the alarm. When the operating
parameter rises above this value, the action associated with the alarm is taken.
<milliampere>
- Enter the high threshold alarm value used here.
low_alarm
- (Optional) Specify the low threshold for the alarm. When the operating parameter
falls below this value, the action associated with the alarm is taken.
<milliampere>
- Enter the low threshold alarm value used here.
high_warning
- (Optional) Specify the high threshold for the warning. When the operating
parameter rises above this value, the action associated with the warning is taken.
<milliampere>
- Enter the high threshold warning value here.
low_warning
- (Optional) Specify the low threshold for the warning. When the operating
parameter falls below this value, the action associated with the warning is taken.
<milliampere>
- Enter the low threshold warning value here.
tx_power_threshold
- Specify the threshold of the optic module’s output power.
high_alarm
- (Optional) Specify the high threshold for the alarm. When the operating
parameter rises above this value, the action associated with the alarm is taken.
<mw_or_dbm>
- Enter the high threshold alarm value used here.
low_alarm
- (Optional) Specify the low threshold for the alarm. When the operating parameter
falls below this value, the action associated with the alarm is taken.
<mw_or_dbm>
- Enter the low threshold alarm value used here.
high_warning
- (Optional) Specify the high threshold for the warning. When the operating
parameter rises above this value, the action associated with the warning is taken.
<mw_or_dbm>
- Enter the high threshold warning value here.
low_warning
- (Optional) Specify the low threshold for the warning. When the operating
parameter falls below this value, the action associated with the warning is taken.
<mw_or_dbm>
- Enter the low threshold warning value here.
rx_power_threshold
- Specify the threshold of optic module’s received power.
high_alarm
- (Optional) Specify the high threshold for the alarm. When the operating
parameter rises above this value, the action associated with the alarm is taken.
<mw_or_dbm>
- Enter the high threshold alarm value used here.
low_alarm
- (Optional) Specify the low threshold for the alarm. When the operating parameter
falls below this value, the action associated with the alarm is taken.
<mw_or_dbm>
- Enter the low threshold alarm value used here.
high_warning
- (Optional) Specify the high threshold for the warning. When the operating
parameter rises above this value, the action associated with the warning is taken.
<mw_or_dbm>
- Enter the high threshold warning value here.
low_warning
- (Optional) Specify the low threshold for the warning. When the operating
parameter falls below this value, the action associated with the warning is taken.
<mw_or_dbm>
- Enter the low threshold warning value here.
state
- (Optional) Specify the DDM state to enable or disable. If the state is disabled, no DDM
action will take effect.
enable
- Specify to enable the DDM state.
disable
- Specify to disable the DDM state.
shutdown
- (Optional) Specify whether or not to shutdown the port when the operating
parameter exceeds the corresponding alarm threshold or warning threshold.
alarm
- Shutdown the port when the configured alarm threshold range is exceeded.
warning
- Shutdown the port when the configured warning threshold range is exceeded.
none
- The port will never shutdown regardless if the threshold ranges are exceeded or not.
Summary of Contents for xStack DGS-3120 Series
Page 1: ......
Page 186: ...xStack DGS 3120 Series Layer 3 Managed Gigabit Ethernet Switch CLI Reference Guide 181...
Page 204: ...xStack DGS 3120 Series Layer 3 Managed Gigabit Ethernet Switch CLI Reference Guide 199...
Page 363: ...xStack DGS 3120 Series Layer 3 Managed Gigabit Ethernet Switch CLI Reference Guide 358...
Page 1056: ...xStack DGS 3120 Series Layer 3 Managed Gigabit Ethernet Switch CLI Reference Guide 1051...