config power_saving mode
{length_detection | link_detection | led | port | hibernation} [enable |
disable]
config power_saving hibernation
[[add | delete] time_range <range_name 32> |
clear_time_range]
config power_saving led
[[add | delete] time_range <range_name 32> | clear_time_range]
config power_saving port
[<portlist> | all] [[add | delete] time_range <range_name 32> |
clear_time_range]
show power_saving
{length_detection | link_detection | led | port | hibernation}
config led state
[enable | disable]
show led
78-1
config power_saving mode
Description
This command is used to set the power saving state.
For link detection and length detection function, they apply to the ports with copper media. If the
power saving link detection state is enabled, the power is saved by following mechanisms:
•
When no links are detected on the port, the port will automatically turn off and will only wake
up the second a single link pulse is sent. While the port is turned off, a simple energy-detect
circuit will continuously monitor energy on the cable. The moment energy is detected; the port
will turn on fully as to the IEEE specification’s requirements. The power saving function is
performed while no link is detected and it will not affect the port capabilities while the link is up.
•
When a link is detected on the port, for a shorter cable, the power consumption will be
reduced by lowering the signal amplitude, since the signal attenuation is proportional to the
cable length. The port will adjust the power based on the cable length and still maintain error
free applications from both sides of the link. This mechanism is only available using the
hardware support cable diagnostics function.
If the power saving state of port is disabled, all power saving schedules of port will not take effect.
If the power saving state of port LED is disabled, all power saving schedules of port LED will not
take effect.
If the power saving state of system hibernation is disabled, all power saving schedules of system
hibernation will not take effect.
Format
config power_saving mode {length_detection | link_detection | led | port | hibernation}
[enable | disable]
Parameters
length_detection
- (Optional) Specify the power saving link detection state.
link_detection
- (Optional) Specify the length detection used.
Summary of Contents for xStack DGS-3120 Series
Page 1: ......
Page 186: ...xStack DGS 3120 Series Layer 3 Managed Gigabit Ethernet Switch CLI Reference Guide 181...
Page 204: ...xStack DGS 3120 Series Layer 3 Managed Gigabit Ethernet Switch CLI Reference Guide 199...
Page 363: ...xStack DGS 3120 Series Layer 3 Managed Gigabit Ethernet Switch CLI Reference Guide 358...
Page 1056: ...xStack DGS 3120 Series Layer 3 Managed Gigabit Ethernet Switch CLI Reference Guide 1051...