background image

 

 

 

 

 
 

 
 
 
 

The lightning flash with an arrowhead symbol, within an equilateral 

triangle is intended to alert the user to the presence of uninsulated 

dangerous voltage within the product's enclosure that may be of 

sufficient magnitude to constitute a risk of electric shock to persons. 

 

The exclamation point within an equilateral triangle is intended to alert 

the user to the presence of important operating and maintenance 

(servicing) instructions in the literature accompanying the appliance. 

 

INFORMATION - 

This equipment has been tested and found to comply with limits for a 

Class A digital device, pursuant to part 15 of the FCC Rules. 

These limits are designed to provide reasonable protection against harmful interference 

when the equipment is operated in a commercial environment. 

This equipment generates, uses, and can radiate radio frequency energy and, if not 

installed and used in accordance with the instruction manual, may cause 

harmful interference to radio communications. 

Operation of this equipment in a residential area is likely to cause harmful interference in 

which case the user will be required to correct the interference at his own expense. 

 

WARNING - 

Changes or modifications not expressly approved by the 

manufacturer could void the user’s authority to operate the equipment. 

CAUTION : 

To prevent electric shock and risk of fire hazards: 

Do NOT use power sources other than that specified. 

Do NOT expose this appliance to rain or moisture.

 

 

This installation should be made by a qualified service person and should conform 

to all local codes

 

 

Summary of Contents for DCC 600d Series

Page 1: ...COLOR DOME TYPE CAMERA 680TVL WDR MANUAL...

Page 2: ...protection against harmful interference when the equipment is operated in a commercial environment This equipment generates uses and can radiate radio frequency energy and if not installed and used i...

Page 3: ...3 1 Features 4 2 Precautions 5 3 Cable Connection OSD Control 6 4 Camera Operation 7 5 Troubleshooting 15 6 Dimensions OSD Board 16 7 Specifications 18 Contents...

Page 4: ...aytime conditions to provide optimum colors and B W mode operates in night time conditions to enhance the definition of the image OSD On Screen Display This camera supports the OSD function which is u...

Page 5: ...e lighting change or flicker can cause the camera to work improperly It is one of the most important parts of the camera Be careful not to be stained by fingerprint If it gets wet wipe it dry immediat...

Page 6: ...ngs after changing the value of the selected function or current conditions UP DOWN buttons Used for selecting items by moving the cursor up or down on the menu screen LEFT RIGHT buttons Used when cha...

Page 7: ...he lens AUTO MANUAL EXPOSURE The function is used to adjust camera Exposure BRIGHTNESS 0 255 Set the screen brightness SHUTTER 1 60 1 50 1 100 1 120 1 250 1 500 1 1K 1 2K 1 4K 1 10K Set the shutter sp...

Page 8: ...just the pull in speed ATW DELAY CNT 0 255 Set the time based hysteresis of ATW ATW FRAME x0 5 x1 00 x1 50 x2 00 Set the pull in frame magnification ENVIROMENT Indoor Outdoor Set the pull in frame of...

Page 9: ...the Red gain in the WB fixed gain mode ANTI CR Color rolling suppression MANUAL Manual white balance Set the B and R gain values for manual WB PUSH LOCK Hold WDR This function is used to set Wide Dyn...

Page 10: ...ation transfer time DAY NIGHT 000 255 Set the threshold for identifying the Night status from the Day status NIGHT DAY 000 255 Set the threshold for identifying the Day status from the Night status SM...

Page 11: ...DELAY CNT 000 255 Set the Night Day identification transfer time DAY NIGHT 000 255 Set the threshold for identifying the Night status from the Day status NIGHT DAY 000 255 Set the threshold for ident...

Page 12: ...s used to set up to eight privacy masks AREA SEL 1 15 2 15 3 15 4 15 5 15 6 15 7 15 8 15 9 15 10 15 11 15 12 15 13 15 14 15 15 15 Select the mask frame to be adjusted MODE Set the privacy zone to ON o...

Page 13: ...MODE OFF ON Control the ON OFF status of the motion detection block display TOP 000 015 Set the top side of the monitoring frame selected by the AREA SEL parameter BOTTOM 000 015 Set the bottom side...

Page 14: ...amera VERSION displays LANGUAGE Multi Language The function is used to select the language in which to display the internal OSD menu EXIT SAVE All the settings of the internal OSD menu are saved NOT S...

Page 15: ...check if an auto iris lens is being used and adjust the brightness level There is a problem with the camera operation Please check if an appropriate power source to the camera complies with the manufa...

Page 16: ...16 DOME CAMERA N1 N2 N3 6 Dimensions OSD Board Configurations...

Page 17: ...17 N4 VANDAL DOME CAMERA N5 N6...

Page 18: ...18 IR VANDAL DOME CAMERA N7...

Page 19: ...D English Japaness German French Russian Portuguese Spanish Chinese ATW 1800 10500K AGC Level setting BackLight BLC WDR 60dB HLC White Balance ATW PUSH USER1 USER2 ANTICR MANUAL PUSH LOCK DNR Off 3D Y...

Page 20: ...8W Max 2 5W Max 2 5W Max 2 5W Power Supply DC12V 10 2V 14 5 V DC 12 V 500mA 10 2V 14 5 V Dual Voltage Option AC24V DC12V Number 5 6 7 LED x x 30LEDs 750nm Visibility Range x x 30m Install Type Outdoor...

Page 21: ...21...

Reviews: