13
INSTALLATION INSTRUCTIONS
Water drainage:
- During dehumidifying modes, remove the
upper
drain plug from the back of the unit, install the
drain connector(5/8 universal female mender)
with 3 4 hose(locally purchased). For the
models without drain connector, just attach the
drain hose to the hole. Place the open end of
the hose adaptor directly over the drain area in
your basement floor. Please refer to Fig.20a.
- During heating pump mode, remove the lower
drain plug from the back of the unit, install the
drain connector(5/8 universal female mender)
with 3/4 hose(locally purchased). For the
models without drain connector, just attach the
drain hose to the hole. Place the open end of
the hose adaptor directly over the drain area in
your basement floor. Please refer to Fig.20b.
NOTE:
Make sure the hose is secure so there are no
leaks.Direct the hose toward the rain,making
sure that there are no kinks that will stop
the warter flowing.Place the end of the hose
into the drain and make sure the end of the
hose is down to let the water flow smoothly.
(See Fig.20a,20b,21a).Do never let it up.(See
Fig.21b).
- When the water level of the bottom tray
reaches a predetermined level, the unit beeps
8 times, the digital display area shows P1 . At
this time the air conditioning/dehumidification
process will immediately stop. However, the fan
motor will continue to operate(this is normal).
Carefully move the unit to a drain location,
remove the bottom drain plug and let the
water drain away(Fig.22). Reinstall the bottom
drain plug and restart the machine until the P1
symbol disappears. If the error repeats, call for
service.
NOTE: Be sure to reinstall the bottom drain plug
before using the unit.
Fig. 20b
Fig. 20a
Fig. 22
Fig. 21b
Fig. 21a
Continuous
drain hose
Drain hose
adaptor
Remove the
upper drain plug
Continuous
drain hose
Drain hose
adaptor
Remove the
lower drain plug