Table 13-4
Model(s):
CSAD UiAWP 100 PS
Air-to-water heat pump:
YES
Water-to-water heat pump:
NO
Brine-to-water heat pump:
NO
Low-temperature heat pump:
YES
Equipped with a supplementary heater:
NO
Heat pump combination heater:
NO
Declared climate condition:
AVERAGE
Parameters are declared for low-temperature application.
Item
Symbol
Value
Unit
Item
Symbol
Value
Unit
Rated heat output (*)
Prated
20.8
KW
Seasonal space heating
energy efficiency
η
s
128
%
Declared capacity for heating for part load at outdoor
temperature Tj
Declared coefficient of performance or primary energy ratio for part load at
outdoor temperature Tj
Tj = -7
℃
Pdh
18.47
KW
Tj = -7
℃
COPd
2.56
-
Tj = 2
℃
Pdh
10.26
KW
Tj = 2
℃
COPd
3.64
-
Tj = 7
℃
Pdh
6.69
KW
Tj = 7
℃
COPd
4.73
-
Tj = 12
℃
Pdh
6.63
KW
Tj = 12
℃
COPd
6.04
-
Tj=bivalent temperature
Pdh
18.47
KW
Tj=bivalent temperature
COPd
2.56
-
Tj = operating limit
Pdh
21.18
KW
Tj = operating limit
COPd
2.25
-
For air-to-water heat pumps:
Tj = -15
℃
Pdh
-
KW
For air-to-water heat pumps: Tj = -15
℃
COPd
-
-
Bivalent temperature
Tbiv
-7
℃
For air-to-water heat pumps: Operation limit
temperature
TOL
-10
℃
Cycling
interval
capacity
forheating
Pcy ch
-
KW
Cycling interval efficiency
COPcy c
-
-
Degradation co-efficient (**)
Cdh
0.9
--
Heating water operating limit temperature
WTOL
-
℃
Power consumption in modes other than active mode
Supplementary heater
Off mode
P
off
0.075
kW
Rated heat output (**)
P
sup
-
-
Standby mode
Psb
0.075
kW
Thermostat-off mode
Pto
0.5
kW
Type of energy input
-
Crankcase heater mode
Pck
0.075
kW
Other items
Capacity control
variable
For air-to-water heat pumps: Rated air flow
rate, outdoors
-
12500
㎥
/h
Sound power level, outdoors
LWA
78
dB
For water- or brine-to-water heat pumps: Rated
brine
or
water
flow
rate,
outdoor
heatexchanger
-
-
㎥
/h
Annual energy consumption
QHE
13189
kWh
For heat pump combination heater:
曾晓静
曾晓静
-
Water heating energy fficiency
η
wh
-
%
Daily electricity consumption
Qelec
-
kWh
Daily fuel consumption
Qf uel
-
kWh
Annual electricity consumption
AEC
-
kWh
Annual fuel consumption
AFC
-
GJ
(*) For heat pump space heaters and heat pump combination heaters, the rated heat output Prated is equal to the design load for heating
Pdesignh, and the rated heat output of a supplementary heater Psup is equal to the supplementary capacity for heating sup(Tj).
(**) If Cdh is not determined by measurement then the default degradation coefficient is Cdh = 0,
Information requirements for heat pump space heaters and heat pump combination heaters
Declared load profile
51
Installation Manual___________________________________________________________________________________
Summary of Contents for CSAD UiAWP 100 PS Series
Page 56: ...dcitsu...