4. IMPORTANT INFORMATION ON
REFRIGERANT
5. PRECAUTIONS OF INSTALLATION
NOTE
The selected installation site of the unit should facilitate connection
of water pipes and wires, and be free from water inlet of oil fume,
steam or other heat sources. Besides, the noise of the unit and cold
and hot air should not influence the surrounding environment.
This product contains fluorinated greenhouse gases covered
by the Kyoto Protocol. Do not vent gases into the atmosphere.
Refrigerant type:
R410A
GWP value: 2088
GWP = global warming potential
5.1 Units can be installed on the ground or proper place on a roof,
provided that sufficient ventilation can be guaranteed.
5.2 Do not install the unit in a scenario with requirements on noise
and vibration.
5.3 When installing the unit, take measures to avoid exposure to
direct sunlight, and keep the unit away from boiler pipeline and
surroundings which might corrode the condenser coil and copper
pipes.
5.4 If the unit is within the reach of unauthorized personnel, take
protective measures for safety considerations, such as installing a
fence. These measures can prevent man-caused or accidental
injuries, and can also prevent the electrical parts in operation from
being exposed when the main control box is opened.
5.5 Install the unit on a foundation at least 300 mm high above the
ground, where the floor drain is provided, to ensure that water
does not accumulate.
5.6 If installing the unit on the ground, put the steel base of the
unit on the concrete foundation, which must be as deep as into
the frozen soil layer. Ensure the installation foundation is
separated from buildings, as the noises and vibration of the unit
may adversely affect the latter. By means of the installation holes
on the unit base, the unit can be fastened on the foundation
reliably.
5.7 If the unit is installed on a roof, the roof must be strong
enough to bear the weight of the unit and the weight of
maintenance personnel. The unit can be placed on the concrete
and groove-shaped steel frame, similar to the case when the unit
is installed on the ground. The weight-bearing groove-shaped
steel must match the installation holes of the shock absorber and
is wide enough to accommodate the shock absorber.
5.8 For other special requirements for installation, please consult
the building contractor, architectural designer or other
professionals.
Model
Refrigerant
(
kg) Tonnes CO
2
equivalent
10.50
17.00
27.00
21.94
35.50
56.36
Factory charge
CSAD UiAWP 100 PS
CSAD UiAWP 200 PS
CSAD UiAWP 300 PS
Table 4-1
Left view
Top view
6.1.2
CSAD UiAWP 200 PS
E
D
F
A
A
B
C
B
Left view
6. INSTALLATION OF THE UNIT
6.1 Outline dimensional drawing
6.1.1
CSAD UiAWP 100 PS
Front view
Fig. 6-1 Outline dimensional of
CSAD UiAWP 100 PS