background image

DAITSU RHR-CFULL WIRELESS CONTROL

The Daitsu RHR-CFULL wireless control is a user and insta-
llation interface for monitoring and configuring the connec-
ted heat recovery unit.

•  This unit allows the quality of the indoor air to be con-

trolled by varying the fan speed. 

•  The device uses a wireless connection (RF) to commu-

nicate with the central unit (heat recovery unit).

SPECIFICATIONS

A

   OK button

B

   Back button

C

   + / Up button

D

   - / Down button

E

   Menu button

Binding the ventilation unit (VU) 
and the wireless multi-control unit

1.

  Press the MENU button for 10 seconds until the configuration 

menu icon appears  .

2.

  If the unit is not bound, by pressing the MENU button again, the 

binding icon will appear 

. Then press the OK button.

3.

  The icon starts to flash when searching for the VU.

    a.  If it is bound correctly, the screen shows BND.
    b.  If it is not bound correctly, the screen shows NO BND.

4.

  If necessary, you can exit by tapping the BACK button to return to 

the configuration menu, or to go back to the home screen.

IMPORTANT:

 the VU will be visible for binding for 10 minutes after 

it is connected to the power supply. If the binding has not occurred 
in 10 minutes, the VU must be restarted by disconnecting it from 
the power supply and reconnecting it so that it is available again for 
binding for 10 minutes.

Selecting the mode and the ventilation speed

From the home screen, the ventilation speed can be changed immedi-
ately by pressing the + and – buttons. 

Speed

High

At home

Low

Absence

Icon

AUTO

AUTO

AUTO

AUTO

Once high speed is reached, if you press the + button, the AUTO in-
dication lights up, showing that you are in automatic speed selection 
mode (regulated by probes or timing).
If the AUTO indication does not appear, you are in manual speed 
selection mode.
By pressing the + button again, you will enter the timer mode. An in-
dication icon will appear on the screen in the form of an hourglass  .

Icons on the LCD screen

A

   Timer  mode.

B

   Maximum  mode.

C

   Absence  mode.

D

   Change filter / Reset filter.

E

   Fan  speed.

  

It can be seen in one of these 4 icons:

     

Speed

High

At home

Low

Absence

Icon

AUTO

AUTO

AUTO

AUTO

F

  

AUTO 

mode of the ventilation unit.

 

 When AUTO is not shown, the fan speed is in MANUAL mode.

G

   Display of 4-digit real value.

H

   Display of 2-digit real value.

I

   Fault indicator (it can be combined with other icons).

J

   Configuration  mode.

K

   Link  mode.

L

   Time setting menu.

M

  “On” program enabled / “Off” program disabled.

N

   Programming activation periods.

O

   Days of the week.

P

   Bypass  indicator.

If you are not on the default screen, tap the 

BACK 

 button.

 

AUTOMATIC MODE

 

ABSENCE MODE

To start 

ABSENCE

 mode, tap the 

UP

   button or 

DOWN

   button over 

and over until the   icon lights up.

To start 

AUTO

 mode, tap the 

UP

   button or the 

DOWN

   button over 

and over until the 

AUTO

 icon lights up.

 

MANUAL MODE

When in 

AUTO

 mode, use the 

UP

   button or the 

DOWN

   button to 

stop 

AUTO

 mode. Tap the 

UP 

or 

DOWN

 button over and over to select 

the correct speed of the ventilation unit.

 

MAXIMUM MODE

To start 

MAXIMUM

 mode, tap the 

UP

   button or the 

DOWN

   button 

over and over until the    icon lights up.

 

TIMER MODE

To start 

TIMER

 mode, tap the 

UP

   button or the 

DOWN

   button over 

and over until the   icon lights up.

A

B

C

K

J

I

H

G

F

E

D

L

M

N

O

P

Reviews: