background image

Screen travel is stopped automatically in the down and up positions by the limit switches that are preset at the factory. If 

it's necessary to adjust for more or less drop follow the steps below. The case cover must be removed to access the 

motor limit switches.

Remove the front cover of the screen from the back of the screen. Lift front cover up approximately 1/2" and pull away 

from back of screen. See Figure 1.

SETTING THE DOWN LIMIT POSITION

TO REDUCE SCREEN DROP:

Turn the white limit switch screw clockwise to decrease the amount of screen drop. Run the screen down to test 

the stop position. If the screen drops too far, raise the screen about one foot and adjust the limit switch again. 

Repeat until the desired position is set.

TO INCREASE SCREEN DROP:

Turn the white limit switch screw counterclockwise to increase the amount of screen drop. Run the screen down to 

test the stop position. If the screen does not drop enough, raise the screen about one foot and adjust the limit 

switch again. Repeat until the desired position is set. Do not adjust for more drop than what was ordered. At least 

1-1/2 wraps of fabric must remain on the roller.

SCREEN ADJUSTMENT FOR 120V AND 220/240V SCREENS

UP RED LIMIT SWITCH KNOB

TO JUNCTION BOX MOUNTED IN

SCREEN CASE, IN WHICH INTERNAL 

WIRING TERMINATES IN WHITE,

BLACK AND RED LEADS.

IN MULTIPLE CONTROL INSTALLATIONS 
THIS SWITCH IS REPLACED BY THE LOW 
VOLTAGE CONTROL, OPERATED FROM 
PUSH BUTTON STATIONS. SEE DIAGRAM 
Nos. 46967 AND 74425, AVAILABLE UPON 
REQUEST.

OPERATING SWITCH, SWITCH

BOX, AND PLATE FURNISHED

WITH SCREEN. (SPDT WITH

CENTER OFF)

THIS SWITCH CANNOT BE USED WITH LVC.

NOTE: A single switch cannot be used to operate more than

            one screen. Contact the factory for further information.

BLACK DOWN

BLACK

UP

RED

DOWN

AC HOT

OFF

WHITE COMMON

BLACK WITH YELLOW

RED UP

ROCKER

SWITCH

AC COMMON

120 VOLTS

50/60 HZ.

2.5   MAX. AMP.

DOWN WHITE LIMIT 
SWITCH KNOB

MOTOR

EXTERNAL WIRING

TO BE COMPLETED

BY INSTALLER.

SIDE VIEW

OF SWITCH

AND BOX

FIGURE 3

DESIGNER ELECTROL

®

 INSTALLATION

120V  

WIRING DIAGRAM

240 VOLT WIRING DIAGRAM FOR STANDARD WALL SWITCH:

Da-Lite offers two styles of 240 volt wall switches for 

standard operation. Please see wiring diagram included 

in wall switch box included with screen.

4

Summary of Contents for Designer Electrol

Page 1: ...t Post Office Box 137 Warsaw Indiana 46581 0137 Phone 574 267 8101 800 622 3737 Fax 574 267 7804 Toll Free Fax 877 325 4832 www da lite com e mail info da lite com Instruction Book for DESIGNER ELECTROL The Da Lite Difference ...

Page 2: ...th a current rat ing at least equal to that of the appliance should be used Cords rated for less amperage than the appliance may over heat 4 To reduce the risk of electric shock do not disassemble this appliance Contact an authorized service dealer when repair work is required Incorrect reassembly can cause electric shock when the appliance is used subsequently 5 The use of an accessory attachment...

Page 3: ... methods of mounting the screen suspended from ceiling and wall mounted See Figure 2 NOTE Allow 1 2 above screen when mounted for front cover of screen installation and removal 5 Picture surface is centered in case Case extends 5 1 2 beyond surface on either end Do not attach anything to screen slat on the bottom of the screen PRE INSTALLATION s HANGER BRACKET HANGER PIN FRONT COVER BACK OF SCREEN...

Page 4: ...unting to a hollow wall drill 1 2 holes and insert the toggle bolts Then fasten the V bar to the wall with the toggle bolts Now set the case in place on the wall with the V bar of the case nestled into the V bar on the wall FOR CEILING MOUNTING Position and properly anchor screw hooks into ceiling beam or other solid surface Then proceed to use the two D rings that are factory mounted to the top o...

Page 5: ...red position is set Do not adjust for more drop than what was ordered At least 1 1 2 wraps of fabric must remain on the roller SCREEN ADJUSTMENT FOR 120V AND 220 240V SCREENS UP RED LIMIT SWITCH KNOB TO JUNCTION BOX MOUNTED IN SCREEN CASE IN WHICH INTERNAL WIRING TERMINATES IN WHITE BLACK AND RED LEADS IN MULTIPLE CONTROL INSTALLATIONS THIS SWITCH IS REPLACED BY THE LOW VOLTAGE CONTROL OPERATED FR...

Page 6: ...ESTORING LOST ROLLER WRAP 1 Push strap over back of roller 2 Tape end of strap to pocket 3 Feed fabric as you pull strap to draw fabric over top 4 Remove tape and strap Solution a Verify 115 125V or 220 240V If insufficient voltage rewire incom ing electric line b Replace fuse c Reset circuit breaker d Check above Tighten all loose wire connections Correct any improper connections Down Position Ch...

Page 7: ...6 ...

Page 8: ...le by the purchaser and Da Lite is not responsible for damage in shipment To protect yourself against damage or loss in transit insure the product and prepay all transportation expenses THIS WARRANTY IS IN LIEU OF ALL OTHER WARRANTIES EXPRESS OR IMPLIED INCLUDING WARRANTIES AS TO FITNESS FOR USE AND MERCHANT ABILITY Any implied warranties of fitness for use or merchantability that may be mandated ...

Reviews: