TROUBLESHOOTING

SYMPTOM

1. Screen will not operate or will not

go 

“down”

.

Motor does

not 

hum.

Motor

hums.

2. Screen will not move

upward.

Motor does 

not

hum.

Motor

hums.

CAUSE

(a) Blown facility fuse.

(b) Tripped facility circuit breaker.

(c)

No power

to operating switch or

junction box.

Power at junction box.

(d) Thermal overload tripped.

(e) Defective motor, limit switch or

capacitor.

(f) Temporary binding.

(a) Blown facility fuse.

(b) Tripped facility circuit breaker.

(c) No power to operating switch or

junction box.

Power at junction box.

(d) Thermal overload tripped.

(e) Defective motor, limit switch or

capacitor.

(f) Temporary binding.

SOLUTION

(a) Replace facility fuse.

(b) Reset facility circuit breaker.

(c) Check above. Tighten all loose

wire connections. Recheck
wiring. See installation
instructions.

“Down” Position

Check for power across black and
white leads.

(d) Let motor cool down for 15

minutes. Try again.

(e) Replace motor assembly. 

NOTE: Motor is a sealed assembly.

(f) With power 

“off”, 

turn roller by

hand to free binding.

(a) Replace facility fuse.

(b) Reset facility circuit breaker.

(c) Check above. Tighten all loose

wire connections. See above.

“Up” Position

Check for power across red and
white leads.

(d) Let motor cool down for 15

minutes. Try again.

(e) Replace motor assembly.

NOTE: Motor is a sealed assembly.

(f) With power 

“off”, 

turn roller by

hand to free binding.

6

Summary of Contents for ELECTROL

Page 1: ...COMPACT ELECTROL DA LITE SCREEN COMPANY INC 3100 North Detroit Street Post Office Box 137 Warsaw Indiana 46581 0137 Phone 219 267 8101 800 622 3737 Fax 219 267 7804 http www da lite com e mail info d...

Page 2: ...en the picture surface is fully up a limit switch in the motor is tripped and the motor shuts off 8 Check for satisfactory condition by operating screen a few times CAUTION Excessive continuous operat...

Page 3: ...SCREW MACHINE SCREW ADJUSTMENT KNOB NO 2 ADJUSTMENT KNOB NO 1 FIGURE 1 FIGURE 2 NOTE MACHINE AND DRYWALL SCREWS ALONG BOTTOM BOARD MUST BE REMOVED IN ORDER FOR THE PAPER AROUND THE FABRIC TO BE REMOVE...

Page 4: ...For plaster dry wall tile or paneling Bottom of case painted same finish as ceiling Offset mounting recessed above ceiling May be adapted for 3 4 ceiling but cut to 1 4 thick under screen case and pa...

Page 5: ...SWITCH BOX AND PLATE FURNISHED WITH SCREEN SPDT WITH CENTER OFF AC COMMON AC HOT 120V AC 60HZ 1 AMP MAX BLACK WITH YELLOW RED UP SIDE VIEW OF SWITCH BOX THIS SWITCH CANNOT BE USED WITH L V C NOTE A SI...

Page 6: ...ACT ELECTROL INSTALLATION CASE LENGTH FABRIC WIDTH 13 1 2 ALL SIZES 1 1 2 3 4 6 3 4 6 3 4 1 1 2 4 1 4 5 FABRIC HEIGHT x W IDTH AS ORDERED UP TO 84 INCH x 84 INCH MOUNTING BRACKET ELECTRICAL OUTLET MOT...

Page 7: ...limit switch or capacitor f Temporary binding SOLUTION a Replace facility fuse b Reset facility circuit breaker c Check above Tighten all loose wire connections Recheck wiring See installation instru...

Page 8: ...ir or to replace at Da Lite s option the defective part of the merchandise Returns for service should be made to your Da Lite dealer If it is necessary for the dealer to return the screen or part to D...

Reviews: