Restoring Roller Wrap
Executive Electrol
®
Installation
CAUTION! Do not attempt to restore a lost wrap
by adjusting limit switches!
1. Run fabric all the way down.
2. Run fabric up and stop just before door closes.
3. Remove the access panel (2 screws, Fig. 3).
4. Two people with clean hands must carefully grasp the slat
pocket at each end.
5. Gently lift fabric up and ease it over the top of the roller.
CAUTION! Be careful not to crease or damage fabric.
6. Additional wraps must be restored if screen surface continues
to hang beyond bottom of case.
7. Test screen by running fabric up and down several times.
8. Replace access panel.
3 1⁄2"
9 1⁄2"
2 3⁄16"
4 1⁄2"
False Top
Mounting
Brackets
3⁄16" Thick
“L” Bracket
Electrical Outlet
Fabric
Height x Width
As Ordered, Up
To 16' x 16'
Suggested Methods of Installation
TYPE 1 & 2
Offset mounting,
recessed above
ceiling, for plaster, dry wall or paneling.
Door painted same finish as ceiling.
TYPE 1 & 2
Allow 1⁄8" min. clearance all around surface door.
Flush mounting
, recessed above ceiling. For use
with 1/4" max. paneling or installation in existing
ceiling using molding around door.
TYPE 3
Allow 1/4" min. clearance all around
surface door.
Extended mounting,
recessed above
ceiling. For use with acoustical or other
ceiling tile 3⁄4" thick laid over door.
NOTE:
Paint the same as
doors and ceiling or remove
and replace with ceiling tile.
Including Mounting Brackets
Ceiling Tile
3⁄4"
3⁄8"
Approx.
Filler Block
3⁄4"
False Top
1/4" Max.
1⁄8"
2 1⁄2"
1/4"
Picture
Surface
Mounting
Brackets
False Top
Surface Door
Access Door
3⁄4"
1/4" x 1" Screw
& Nut Insert
Drywall Screw
“L” Bracket
1/4" x 2"
Lag Screw
False Top
SHIM
3"
9 7⁄8"
9 1⁄2"
8"
12 1⁄16"
Length of Fabric Width
+ 26 1⁄2", All Sizes
22"
12 1⁄16"
11 5⁄16"
4 3⁄4"
12 1⁄16"