4
FIGURE 5
ELECTRICAL WIRING
Electrical wiring is required for each mask roller motor. The vertical masking systems have one motor at the frame top.
Horizontal masking systems have one motor at the frame top and one at the bottom.
A motor requires standard 120V/220V input. All connections are made to the electrical box on the audience left side of
the unit.
FIGURE 6
SPRING TENSION CABLE
EYE SNAP
EYELET
HORIZONTAL MASK CONNECTION
VERTICAL MASK CONNECTION
HORIZONTAL MASK CONNECTION
SLAT
SURFACE
TAPE STRIP
Tensioning the bottom masking panel
1. Carefully remove all tape strips securing surfaces around rollers. Slats should move freely. See Figure 5.
2. Locate the spring tension cables on either side of the unit.
3. Connect the eye snap to the eyelet on the bottom masking panel bar. See Figure 5. You will need to pull the cable
slightly.
4. Repeat for the other side.
SLAT
Summary of Contents for MULTI-MASK IMAGER
Page 11: ...10 ...