21249
A Milestone AV Technologies Brand
3100 North Detroit Street
Warsaw, Indiana 46582
P: 574.267.8101 or 800.622.3737
F: 574.267.7804 or 877.325.4832
E: info@da-lite.com
www.da-lite.com
DL–0397 (Rev. 1) 03.16
© 2016 Milestone AV Technologies LLC. Printed in U.S.A.
SCB-100 unit will actuate command that was sent.
Click “Transfer” and “Send Text File”
Browse to file location and select appropriate text file and
click “Open”
Usage
To control the screen or lift connected through the SCB-100 to
the NET-100, you will need to create a TCP/IP Winsock
connection through HyperTerminal or other emulator program.
1. You will be required to create (4) text files in a text editor like
Notepad. They will be named Up, Stop, Down and Poll.
Commands
@1u – Motor 1 up
@2u – Motor 2 up
@1d – Motor 1 down
@2d – Motor 2 down
@1s – Motor 1 stop
@2s – Motor 2 stop
@P – Poll (Reports Relay Status)
NOTE:
All commands need to be sent as a continuous string
Example command text file for Up:
2. Create a TCP/IP Winsock connection through HyperTerminal
or other emulator program.
Host Address: 192.168.1.100
Port Number: 10001
The above example will activate Motor 1 and Motor 2 simultaneously.