15. Wire the wall switch supplied with the Da- Lift. See Figure 17.
16. A control panel may be connected to the Da-Lift by using the
wall switch wire leads. The control panel must provide a
momentary, dry contact closure of at least 1/2 second.
a. Use 3-conductor 20-24 AWG wire to connect the control
panel to the wall switch leads. See Figure 17.
b. A momentary closure across the white and red wires will be
an “up” command.
c. A momentary closure across the white and black wires will
be a “down” command.
d. A momentary closure across the white, red, and black wires
will be a “stop” command.
CAUTION: Never apply voltage to the wall switch leads or the
Da-Lift will be damaged.
ATTENTION: N'appliquez jamais une tension aux fils du
commutateur mural sinon le Da-Lift sera endommagé.
Procedure (Continued)
Figure 17
Figure 18
Recommended Wire Size: 20-24 AWG
White Wire
Black Wire
Red Wire
Up
Stop
Down
White Wires
Receiver Cable
Control Box
To IR or RF
Receiver
Port Labeled "Eye"
Cover
Black Wires
Red Wires
17. Optional Infrared (IR) or Radio Frequency (RF) remote controls
are available. To install either remote, remove the Covers from
the Control Box. Route the eceiver Cable through the Da-Lift and
plastic bushing of the Control Box. Plug the Receiver Cable into
the motor control board port labeled “EYE”. See Figure 18.
Plug IR or RF receiver into other end of Receiver Cable.
“Learn” the RF remote and receiver by following the
directions supplied with the RF.