background image

DA-LITE SCREEN COMPANY, INC.

3100 North Detroit Street

Post Office Box 137

Warsaw, Indiana 46581-0137

Phone: 574-267-8101

800-622-3737

Fax: 574-267-7804

Toll Free Fax: 877-325-4832

www.da-lite.com

e-mail: info@da-lite.com

Instruction Book for

TensIoned CosmopolITan® eleCTrol®

For sizes Up To 10'x10'

The Da-Lite Difference.

Summary of Contents for Tensioned Cosmopolitan electrol

Page 1: ...st Office Box 137 Warsaw Indiana 46581 0137 Phone 574 267 8101 800 622 3737 Fax 574 267 7804 Toll Free Fax 877 325 4832 www da lite com e mail info da lite com Instruction Book for Tensioned Cosmopolitan Electrol For Sizes UpTo 10 x10 The Da Lite Difference ...

Page 2: ...completely sealed in recessed installation Allow access for service Picture surface is centered in case Case extends 5 1 2 beyond surface on either end Do not attach anything to screen slat rod or bottom fabric pocket 1 Make sure screen is level Use a carpenter s level and plumb level CAUTION Do not cut wrapping paper or tape with knife or any sharp tool Remove by hand 2 Install electrical hook up...

Page 3: ...SWITCH AND BOX THIS SWITCH CANNOT BE USED WITH LVC NOTE A single switch cannot be used to operate more than one screen Contact the factory for further information DOWN BLACK BLACK UP WHITE RED DOWN AC HOT OFF COMMON WHITE BLACK WITH YELLOW UP RED ROCKER SWITCH AC COMMON 120 V 60 HZ 2 5 MAX AMP 120V WIRING DIAGRAM DOWN WHITE LIMIT SWITCH ADJUSTMENT IN MULTIPLE CONTROL INSTALLATIONS THIS SWITCH IS R...

Page 4: ...r Failure to do so may damage the controller Use 2 conductor 20 24 gauge wire to extend the low voltage connection from the projector s 5 or 12 volt screen trigger output to the length required to reach the VPI When extending the low voltage connection from the projector s screen trigger output polarity does not matter The red and black wires from the VPI are interchangeable GROUND MUST BE CONNECT...

Page 5: ...ll switch is REQUIRED to make any limit switch adjustments EVEN if a third party control system is used Therefore it is advised to wire the switch or provide a 4 conductor connection that is accessible CONNECT SUPPLIED RJ9 CABLE TO SPLITTER AND SWITCH OR USE 4 CABLE CONDUCTOR TO CONNECT TO SCREW TERMINALS The screen surface travel is stopped automatically in the fully opened and closed positions b...

Page 6: ...nt voltage rewire incoming electric line b Replace fuse c Reset circuit breaker d Check above Tighten all loose wire connections Correct any improper connections Down Position Check for power across black and white leads Up Position Check for power across red and white leads e Let motor cool down for 15 minutes Try again f Check for continuity Cut off old splice and reconnect g Replace motor assem...

Page 7: ...6 ...

Page 8: ...e by the purchaser and Da Lite is not responsible for damage in shipment To protect yourself against damage or loss in transit insure the product and prepay all transportation expenses THIS WARRANTY IS IN LIEU OF ALL OTHER WARRANTIES EXPRESS OR IMPLIED INCLUDING WARRANTIES AS TO FITNESS FOR USE AND MERCHANT ABILITY Any implied warranties of fitness for use or merchantability that may be mandated b...

Reviews: