background image

5

 

CAUTION: The projector must be turned off before 
connecting the trigger wires to the projector. Failure to do 
so may damage the controller.

 

ATTENTION: Le projecteur doit être éteint avant de brancher 
les fils de déclenchement à celui-ci. Tout manquement à 
cette instruction pourrait endommager le contrôleur.

Use 2-conductor 20-24 gauge wire to extend the low voltage 
connection from the projector’s 5 or 12-volt screen trigger output 
to the length required to reach the VPI. When extending the low 
voltage connection from the projector’s screen trigger output 
polarity does not matter. The red and black wires from the VPI 
are interchangeable. 

120V Wiring Diagram with Optional Built-In Video Projector Interface

5/12 Volt Screen 
Trigger On Projector

Ground–Must Be Connected 
To Building Ground

UP

STO

P

DOWN

Power Input 120VAC / 60Hz

Green (Ground)

Black (Hot)

White (Common)

Power 

Wire

Data Cable

RJ-45 Jack

RJ-45 Receptacle

RJ-22 Output 

RJ-22 Jack

RJ-22

Inputs

RJ-22

Jack

LED

Up  

Limit 

Tactile  

Button

Down  

Limit 

Tactile  

Button

Front Of  

Wall Switch

Back Of 

Wall Switch

Black

Red

VPI Trigger Module

Dry Contacts

Up

Down

Common

Bus

5V

BUS

BUS

COM

5V

BUS

IMPORTANT NOTE: 

The wall switch is REQUIRED to make any 

limit switch adjustments, EVEN if a third party control system is 
used.  Therefore, it is advised to wire the switch or provide a 
3-conductor connection that is accessible.

3-conductor 20-24 gauge wire can be used in place of the 
supplied RJ-14 cable to connect the wall switch.  Connect the 
BUS terminals on the wall switch to the corresponding BUS 
terminals on the splitter board.

Summary of Contents for Tensioned Cosmopolitan Electrol

Page 1: ...INSTRUCTION BOOK FOR Tensioned Cosmopolitan Electrol For Sizes Up To 10 x 10 ...

Page 2: ...e manufacturer may cause a risk of fire electric shock or injury to persons Save These Instructions Pre Installation Installation NOTE Under no circumstances should unit be completely sealed in recessed installation Allow access for service Picture surface is centered in case Case extends 5 1 2 beyond surface on either end Do not attach anything to screen slat rod or bottom fabric pocket 1 Make su...

Page 3: ... Down Black Black Up White Red Down AC Hot Off Common White Black With Yellow Up Red Rocker Switch AC Common 120 V 60 Hz 2 5 Max Amp To Junction Box Mounted In Screen Case In Which Internal Wiring Terminates In White Black and Red Leads Motor End 3 4 Diameter Hole For Wall Installation Overall Length of Case Between Hanger Eyes Overall Length of Slat Slat Picture Surface Enclosure Cover 3 8 Diamet...

Page 4: ...witch Connect the BUS terminals on the wall switch to the corresponding BUS terminals on the splitter board IMPORTANT NOTE The wall switch is REQUIRED to make any limit switch adjustments EVEN if a third party control system is used Therefore it is advised to wire the switch or provide a 3 conductor connection that is accessible RJ 14 Pin Outs Tab Is Facing Up Supplied RJ 14 cable Bus RP Data RQ D...

Page 5: ...deo Projector Interface 5 12 Volt Screen Trigger On Projector Ground Must Be Connected To Building Ground UP STOP DOWN Power Input 120VAC 60Hz Green Ground Black Hot White Common Power Wire Data Cable RJ 45 Jack RJ 45 Receptacle RJ 22 Output RJ 22 Jack RJ 22 Inputs RJ 22 Jack LED Up Limit Tactile Button Down Limit Tactile Button Front Of Wall Switch Back Of Wall Switch Black Red VPI Trigger Module...

Page 6: ... Low Voltage Wall Switch Optional IR and RF Remote Control Splitter Motor Ground to Case 240VAC 50Hz 240V Wiring Diagram With Optional Built In Low Voltage Control Up Stop Down Ground Must be Connected to Building Ground Green Front Back UP DN GND 5V 3 Position Switch RJ9 UP 5V COM DN IMPORTANT NOTE The wall switch is REQUIRED to make any limit switch adjustments EVEN if a third party control syst...

Page 7: ...Replace motor assembly NOTE Motor is a sealed assembly Temporary binding With power off turn roller by hand to free binding Capacitor burned out Replace motor assembly Incorrect stopping position in downward direction Down limit switch out of adjustment Contact Da Lite at 800 622 3737 or 574 267 8101 Incorrect stopping position in upward direction Up limit switch out of adjustment Contact Da Lite ...

Page 8: ...MAXIMUM EXTENT PERMITTED BY APPLICABLE LAW THIS WARRANTY IS IN LIEU OF ALL OTHER WARRANTIES EXPRESS OR IMPLIED INCLUDING WARRANTIES AS TO FITNESS FOR USE AND MERCHANTABILITY Any implied warranties of fitness for use or merchantability that may be mandated by statute or rule of law are limited to the one 1 year warranty period This warranty gives you specific legal rights and you may also have othe...