EE Pro for TI-89.92 Plus
Analysis - Ladder Networks
24
1. Enter the frequency and load values:
Frequency:
10,000 Hz.
Load:
5000 ohms.
2. Enter the ladder elements in the following order:
Capacitor:
Parallel, 318E-12.
Current-Controlled I:
Enter 2500 ohms for
RB
and 100 for
β.
Resistor:
Parallel, 1E6 ohms.
Capacitor:
Series, 0.638E-6 farads.
3. Press
„
to compute the results, which are displayed in the output screen above.