ENGLISH 

 

12 

 

The pump is suitable for vertical or horizontal installations. 

 

Connect a rigid or flexible pipe to the 1¼” delivery of the pump. 

 

The maximum submersibility of the pump depends on the length of the power cable: 12m (39.4 ft) in the case of a cable 15m (49.2 ft) long; 7m 

(23 ft) in the case of a cable 10m (32.8 ft) long. Check the details on the technical data plate, as shown in figure 4. 

 

In order to always guarantee a good water flow, it is advisable not to exceed the following heights between the service taps and the pump (see 

figure 7). 

 

45/90 

35/120 

35/90 

20 m (65.6 ft) 

13 m (42.6 ft) 

13 m (42.6 ft) 

 

 

To facilitate installation in the tank, it is possible to remove the power cable and/or pass it through another passage hole. To 

remove it, follow the instructions on the product's quick guide. The electrical cable has a quick connection. 

Have this operation carried out by qualified personnel. Check the earth connection before commissioning the product. 

 

The pump has: 

 

An air vent valve (see figure 8). This valve allows the pump to prime in a very short time. If the water level is lower than the valve level, 

some water may escape from the vent valve. 

 

A small spring and diaphragm expansion tank (in the case of DTRON2 pumps). This limits the number of pump restarts and 

compensates for small system losses. The tank protects the pump in case of water hammer. The tank does not require any refilling or 

maintenance.  

 

An overpressure valve, which prevents water hammer. In case of ice in the delivery pipe with a submerged pump, this valve protects 

the pump from breakage. 

Installation in a well. 

Install the pump so that the pump suction is at least 1 m (3.28ft) above the bottom of the well to prevent the intake of sand and impurities. Use 

rigid metal pipes to hang the pump and secure the pipes with brackets at the top of the well. 

 

Installation in a tank 

The minimum dimensions for the pump passage in the collecting tank are 180x185 mm (7.09x7.28 in). 

Hold the pump slightly up from the bottom so as to avoid possible noises/vibrations transmitted to the tank. 

The pump will make noise if it is placed on the bottom of the tank. 

 

To avoid obstruction of the suction passages, it is recommended to check periodically that no dirt has accumulated in the 

collection trap (leaves, sand, etc.). 

 

Installation with FLOAT KIT (accessory) 

In the case of DTRON2 pumps, an NFC level float can be added. 

This accessory, once placed in the appropriate seat in the pump, communicates with the electronic board without the aid of electrical 

connections. 

The minimum overall dimensions of the pump with float inside a well or tank are as follows: 

The minimum recommended distance between the end of the pump float and the wall is 3cm (1.18 in) (see figure 10). 

The minimum recommended distance between the float of the suction pipe and the wall (in the case of version X) is 10cm (3.94 in) (see figure 

10). 

 

 

3

 

FIRST INSTALLATION 

 

The pump and the control panel, if present, must be connected to the same power mains, avoiding their being galvanically 

separated, as for example due to the presence of open isolation transformers or switches, even single-phase ones.  

In particular condominium or industrial contexts, where single-phase users can be connected to different phases of the three-

phase distribution provided by the public operator, the control panel and the pump might not be able to communicate. 

 

 

Summary of Contents for DTRON2 35/120

Page 1: ...Fig Fig Image Abb Afb Fig Obr Kuva Fig Fig ekil Rys bra Fig Fig 1 Fig 2 Fig 3 Fig 5...

Page 2: ...Fig 6 Fig 7 Fig 8 Fig 9...

Page 3: ...Fig 10 Fig 11...

Page 4: ...onnel in possession of the technical qualifications required by the specific legislation in force The term skilled personnel means persons whose training experience and instruction as well as their kn...

Page 5: ...y or useful without affecting their essential characteristics 1 GENERAL 1 1 Applications Multistage submerged pump with integrated electronics ideal for use in rainwater systems and irrigation network...

Page 6: ...0 04 in 1 3 Technical Data DTRON2 pumps are equipped with a filter which can be opened see figure 1 A or closed called X see figure 1 B depending on the application The open filter prevents the passa...

Page 7: ...n force 2 1 Mechanical Installation Install the pump in a location that is not exposed to freezing When the pump remains inactive at a temperature lower than 0 C it is necessary to ensure that there i...

Page 8: ...a well Install the pump so that the pump suction is at least 1 m 3 28ft above the bottom of the well to prevent the intake of sand and impurities Use rigid metal pipes to hang the pump and secure the...

Page 9: ...ee ANTI DRYRUN function Various alarms 4 2 Pump On OFF The pump motor is powered by the electronic control board located inside the pump body with an alternating voltage equal to that of the electrica...

Page 10: ...mains Once the pump has been removed from the liquid it is advisable to clean the following parts with a simple jet of water Filter open see figure 1A Suction filter with float in case of version X se...

Reviews: