ENGLISH
65
QUICK CLEAN
The “QuickClean” key allows you to perform a rapid wash of the system or fast recirculation, for example by cleaning,
suction, adding chemicals, and so on.
PARAMETERS
VALUES
DESCRIPTION
Speed
20% - 100%
Setting the speed with fixed curve
control (in percentage%)
TIme
1 min - 10 h
Setting the duration time at the
relative speed.
The duration value indicates the time
that the speed remains active, after
which it ends.
5.3 Control with Timers
TIMER CONTROL
This menu allows you to set the automatic filtration cycles of the electronic pump. The parameters related to the
different speeds (S5-8), the start and stop times of each cycle (up to 8 cycles: A-H) and the day of the week are set.
In addition, from the "Preset Timers" menu, you can select an already set basic filtration cycle from which to start to
configure the most suitable cycle for your needs.
SPEED WITH TIMERS
This menu items allows you to view and change the parameters associated with the speeds from 5 to 8 managed by
the timers.
PARAMETERS VALUES
DESCRIPTION
Control Mode
FLOW/SPEED The first choice to make is whether
you want the setpoints “SET5-8” to
set the system regulation mode to
“Flow” or “Speed %”.
S5-S8
E.swim 150
5 - 25 m3/h (o
20 ÷ 110
GPM)
E.swim 300
13 ÷ 32 m3/h
(o 60 ÷ 140
GPM)
Setting the speed with flow control.
20% - 100%
Setting the speed with fixed curve
control (in percentage%)
The speeds from 5 to 8 cannot be loaded from the keyboard, but they
are activated and deactivated only by the TIMERS system. Unlike
speeds 1-4, they do not have any associated duration, as the activation
time is decided always and only by the TIMERS.
SETTING OF THE TIMERS
There are eight different timers on the machine, from
Timer A
to
Timer H
, each of which allows timed starting and
stopping, on a weekly basis, of a setpoint chosen from
Set Points 5-8
.
With a simple setting you can thus automatically carry out all the desired cycles, repeated weekly.
PARAMETERS
VALUES
DESCRIPTION
Enable Timer ("E")
The possibility of enabling or disabling a timer
may be useful, for example, at the change of
season, allowing you to exclude a timer but
leaving all its data set to be used again later.
the START time
00:00 - 23:59
sets the time of
starting the work
cycle
the STOP time
00:01 - 24:00
sets the time of
ending the work
cycle
Desired speed ("S")
S5-S8
Selects one of the
4 speeds for the
set work cycle