7.5.3 - AD: Address configuration
7.5.3 - AD: Address configuration
This is significant only in a multi-pump connection. Set the communication
This is significant only in a multi-pump connection. Set the communication
address to be assigned to the device. The possible values are: automatic
address to be assigned to the device. The possible values are: automatic
(default) or manually assigned address.
(default) or manually assigned address.
The addresses set manually can have values form 1 to 4. The configura
-
The addresses set manually can have values form 1 to 4. The configura
-
tion of the addresses must be the same for all the devices that make up
tion of the addresses must be the same for all the devices that make up
the group: either all automatic or all manual. Setting the same addresses
the group: either all automatic or all manual. Setting the same addresses
is not allowed.
is not allowed.
Both in the case of assigning mixed addresses (some manual and some
Both in the case of assigning mixed addresses (some manual and some
automatic) and in the case of duplicate addresses, an error signal is giv
-
automatic) and in the case of duplicate addresses, an error signal is giv
-
en. The error signal is given by displaying a flashing E in the place of the
en. The error signal is given by displaying a flashing E in the place of the
machine address.
machine address.
If the chosen assignment is automatic, whenever the system is switched
If the chosen assignment is automatic, whenever the system is switched
on addresses are assigned that may be different from the previous time,
on addresses are assigned that may be different from the previous time,
but this does not affect correct operation.
but this does not affect correct operation.
7.5.4 - MS: Measuring system
7.5.4 - MS: Measuring system
Set the measuring system, choosing between metric and
Set the measuring system, choosing between metric and Anglo-American
units. The quantities displayed are shown in Table 12.
units. The quantities displayed are shown in Table 12.
Units of measurement displayed
Quantity
Metric units
Anglo-American unit
Pressure
bar
psi
Temperature
°C
°F
Flow rate
l / min
gal / min
NOTE:
The flow in Anglo-American-speaking units (gal/min) is indicat
-
ed adopting a conversion factor of 1 gal = 4.0 litres, corresponding to
the metric gallon.
Table 12: Measuring system
7.5.5 - AS: Association of devices
7.5.5 - AS: Association of devices
Allows connection/disconnection with the following devices
Allows connection/disconnection with the following devices
•
•
e.sy
Other e.sybox pump for operation in a pump set
e.sy
Other e.sybox pump for operation in a pump set
•
•
composed of max 4 elements
composed of max 4 elements
•
•
e.sylink e.sylink input output control unit
e.sylink e.sylink input output control unit
•
•
DEV
Any other compatible devices
DEV
Any other compatible devices
The icons of the various connected devices are displayed on page AS with
The icons of the various connected devices are displayed on page AS with
below an identifying acronym and the respective reception power.
below an identifying acronym and the respective reception power.
An icon lit with a fixed light means that the device is connected and work
-
An icon lit with a fixed light means that the device is connected and work
-
ing correctly; a stroked through icon means the device is configured as
ing correctly; a stroked through icon means the device is configured as
part of the network but is not found.
part of the network but is not found.
All the devices present over the air are not displayed on this page
All the devices present over the air are not displayed on this page
but only the devices that have been associated with our network.
but only the devices that have been associated with our network.
Seeing only the devices in your own network allows the operation
Seeing only the devices in your own network allows the operation
of several similar networks existing within the radius of action of
of several similar networks existing within the radius of action of
the wireless without creating ambiguity; in this way the user does
the wireless without creating ambiguity; in this way the user does
not see the elements that do not belong to his pumping system.
not see the elements that do not belong to his pumping system.
From this menu page it is possible to associate and disassociate an ele
-
From this menu page it is possible to associate and disassociate an ele
-
ment from your personal wireless network.
ment from your personal wireless network.
When the machine starts the AS menu item does not show any connection
When the machine starts the AS menu item does not show any connection
because no device is associated. In these conditions the message “No
because no device is associated. In these conditions the message “No
Dev” is shown and the COMM led is off. Only an action by the operator can
Dev” is shown and the COMM led is off. Only an action by the operator can
allow devices to be added or removed with the operations of association
allow devices to be added or removed with the operations of association
and disassociation.
and disassociation.
Association of devices
Association of devices
Pressing ‘+’ for 5 sec puts the machine into the mode where it searches
Pressing ‘+’ for 5 sec puts the machine into the mode where it searches
for wireless association, communicating this status by the blinking of the
for wireless association, communicating this status by the blinking of the
COMM leds at regular intervals. As soon as two machines in a working
COMM leds at regular intervals. As soon as two machines in a working
communication range are put into this status, if possible, they are asso
-
communication range are put into this status, if possible, they are asso
-
ciated with each other. If the association is not possible for one or both
ciated with each other. If the association is not possible for one or both
machines, the procedure ends and a pop-up appears on each machine
machines, the procedure ends and a pop-up appears on each machine
saying “association not possible”. An association may not be possible be
-
saying “association not possible”. An association may not be possible be
-
cause the device you are trying to associate is already present in the max
-
cause the device you are trying to associate is already present in the max
-
imum number or because the device to be associated is not recognised. In
imum number or because the device to be associated is not recognised. In
the last case repeat the procedure from the start.
the last case repeat the procedure from the start.