Factory settings
Identifying
code
Description
Value
Installation Memo
TK
Backlight lighting T
2 min
LA
Language
ENG
SP
Setpoint pressure [bar]
3,0
P1
Setpoint P1 [bar]
2,0
P2
Setpoint P2 [bar]
2,5
P3
Setpoint P3 [bar]
3,5
P4
Setpoint P4 [bar]
4,0
RI
Revs per minute in manual
mode [rpm]
2400
OD
Type of plant
1 (Rigid)
RP
Pressure decrease to
restart [bar]
0,3
AD
Address configuration
0 (Auto)
PR
Remote pressure sensor
Disable
MS
Measuring system
0 (International)
TB
Blockage time for water
lack [s]
15
T1
Low pr. delay (KIWA) [s]
2
T2
Delay in switching off [s]
10
GP
Proportional gain
coefficient
0,5
GI
Integral gain coefficient
1,2
RM
Maximum speed [rpm]
3050
NA
Active devices
N
NC
Simultaneous devices
NA
IC
Configuration of the
reserve
1 (Auto)
ET
Max. switching time [h]
2
AE
Anti-blocking function
1(Enable)
AF
Antifreeze
1(Enable)
I1
Function I1
0 (Disable)
I2
Function I2
0 (Disable)
I3
Function I3
0 (Disable)
I4
Function I4
0 (Disable)
O1
Function output 1
2
O2
Function output 2
2
PW
Change Password
0
AY
Anticycling Function AY
0 (Disabled)
Table 21: Factory settings