20 

3.

 

When the pump is to be in a fixed installation, with a float, a check valve must always be fitted in 

the delivery pipe.  This is also advisable on pumps with manual operation. 

 

ELECTRIC CONNECTION 
CAUTION! ALWAYS FOLLOW THE SAFETY REGULATIONS. 

 

1.

 

Ensure that the mains voltage is the same as the value shown on the motor plate and 
that there is the possibility of 

MAKING A GOOD EARTH CONNECTION.

 

2.

 

Pumping stations must always be provided with an automatic switch with an 
intervention current of less than 30 mA.

 

3.

 

Single-phase motors are provided with built-in thermal overload protection and may 
be connected directly to the mains.  

N.B.

  If the motor is overloaded it stops 

automatically.  

Once it has cooled down it starts again automatically without any 

need for manual intervention.

 

4.

 

Three-phase pumps must be protected with motor protectors suitably calibrated 
according to the values on the data plate of the pump to be installed. The plug on the 
pump must be connected to an EEC socket complete with isolating switch and fuses. 

5.

 

Do not damage or cut the power cable.  If this should occur accidentally, have it 
repaired or replaced by skilled and qualified personnel. 

 
 

CHECKING THE DIRECTION OF ROTATION (for three-phase motors) 

 

(Fig.4) 

The direction of rotation must be checked each time a new 
installation is made. 
Proceed as follows 

(Fig.4)

1.

 

Place the pump on a flat surface.

 

2.

 

Start the pump and stop it immediately.

 

3.

 

Carefully observe the kick-back on starting, looking at the 
pump from the motor side.  The direction of rotation is 
correct, that is clockwise, if the protection cap moves as in 
the drawing (anti-clockwise).

 

If it is not possible to check as described above because the pump is already installed, check as 
follows: 
1.

 

Start the pump and observe the water flow rate. 

2.

 

Stop the pump, switch off the power and invert two phases on the supply line. 

3.

 

Restart the pump and check the water flow rate again. 

4.

 

Stop the pump. 

 

The correct direction of rotation will be the one in which the flow rate 
and electric absorption are LOWER! 

 
STARTING UP 

Models with a float switch start up automatically when the water level rises; models without a float 
are started by means of a switch located upstream from the socket (not supplied). 

 
ADJUSTING THE FLOAT SWITCH 

Lengthening or shortening the cable between the float and the fixed point (slot provided in the 
handle - 

Fig.5

) adjusts the START or STOP level of the pump.  Be sure that the float can move 

freely. 

 
 
 
 

Summary of Contents for FEKA VS

Page 1: ...INGEBRUIKNAME EN ONDERHOUD POKYNY K IN TAL CII A DR BE KULLANIM VE BAKIM TAL MATLARI INSTALLATIONS OCH UNDERH LLSANVISNING INSTRUCCIONES PARA LA INSTALACI N Y EL MANTENIMIENTO INSTRU ES PARA A INSTALA...

Page 2: ...VS VX Checking and changing the oil DRENAG 1000 1200 Modifications and spare parts Troubleshooting 17 17 18 18 18 19 20 20 20 20 21 21 22 23 24 24 Anwendungen Technische Daten und Einsatzgrenzen Hinwe...

Page 3: ...e to flooding for pumping drains rainwater traps or infiltrations from gutters excavations etc Thanks to their compact shape and easy manoeuvrability and to the vertical delivery mouth with male threa...

Page 4: ...st never be allowed to run dry 6 The Manufacturer does not vouch for correct operation of the pump if it is tampered with or modified INSTALLATION 1 If the bottom of the well or borehole in which the...

Page 5: ...n the base bracket in contact with the pump suction strainer near the delivery aperture secure everything to the strainer cover with the screws provaided to lock the strainer cover Remove the top scre...

Page 6: ...ired or replaced by skilled and qualified personnel CHECKING THE DIRECTION OF ROTATION for three phase motors Fig 4 The direction of rotation must be checked each time a new installation is made Proce...

Page 7: ...h substances which tend to form a deposit rinse it after use with a powerful jet of water so as to avoid the formation of deposits or scale which would tend to reduce the yield of the pump MAINTENANCE...

Page 8: ...hole 64 and catch it in a container Analyse the oil if you find any particles of water or abrasive materials for example sand it is advisable to check the condition of the mechanical seal 16 and to ha...

Page 9: ...out of the hole of the cap 64 and pour it into a container Analyse the oil if you find any particles of water or abrasive materials for example sand it is advisable to check the condition of the mecha...

Page 10: ...e strainer E The required head is higher than the pump characteristics A Remove the blockage B Change the impeller or remove the blockage C Check that the valve is operating correctly and replace it i...

Page 11: ...evalencia Maximal pumph jd Manometrik y kseklik x tK A Nostokorkeus Wysoko ci nienia Hmax m 2 poles 50 Hz Hmax m 2 poles 60 Hz FEKA VS 550 7 4 7 4 FEKA VS 750 9 6 9 6 FEKA VS 1000 11 8 11 8 FEKA VS 12...

Page 12: ...Fernando De Henares Madrid Spain info spain dwtgroup com Ph 34 91 6569545 Fax 34 91 6569676 PUMPS AMERICA INC DAB PUMPS DIVISION 3226 Benchmark Drive Ladson SC 29456 USA info usa dwtgroup com Ph 1 843...

Reviews: