ENGLISH
73
Quick-view menu (visible)
Full Menu (direct or password access)
Main menu
User menu
mode
Monitor
menu
set-minus
Setpoint
menu
mode-set
Manual menu
set-plus-minus
Installer
menu
mode-set-minus
Tech. Assist.
menu
mode-set-plus
MAIN
(Main page)
FR
Minimum
of rotation
VF
Flow display
SP
Setpoint
pressure
FP
Minimum
Frequency mode
RC
Rated
frequency
TB
Block time
due to water failure
Menu selection
VP
Pressure
TE
Dissipator
temperature
P1
Aux. 1 pressure
VP
Pressure
RT
Direction
of rotation
T1
Shutdown time after
low pressure
C1
Pump phase
current
BT
Card
temperature
P2
Aux. 2 pressure
C1
Pump phase
current
FN
Rated
frequency
T2
Delay on shutdown
PO
Power delivered to
the pump
FF
Fault & Warning
Log
P3
Aux. 3 pressure
PO
Power delivered to
the pump
OD
Type
of system
GP
Integral
gain
SM
System monitor
CT
Contrast
P4
Aux. 4 pressure
RT
Direction
of rotation
RP
Restart
Pressure decr.
GI
Integral
gain
VE
HW and SW
information
LA
Language
VF
Flow display
AD
Address
FS
Minimum
frequency
HO
Operating hours
PR
Pressure sensor
FL
Minimum
frequency
MS
Measurement
system
NA
Active inverters
FI
Flow sensor
NC
Max. simultaneous
inverters
FD
Pipe diameter
IC
Inverter config
FK
K-factor
ET
Max. exchange time
FZ
Zero flow frequency
CF
Carrier
FT
Min. flow
threshold
AC
Acceleration
SO
Dry running factor
Min. threshold
AE
Antiblocking
MP
Min. dry running
pressure
I1
Input 2
function
I2
Input 2
function
I3
Input 2
function
I4
Input 2
function
O1
Output 2
function
O2
Output 2
function
RF
fault & warning
reset
Key
Identification colours
Modification of multi inverter unit parameters
Series of sensitive parameters. These parameters must be aligned to enable start-up of the multi-inverter system.
Modification of one of these parameters on any inverter will automatically align all other inverters without the
need for any command.
Parameters that enable facilitated alignment from a single inverter, transferring data to all others. It is admissible
that these differ between inverters.
Series of parameters that can be aligned in broadcast mode by one inverter only.
Setting parameters significant on a local level only
Read-only parameters
Table 10: Menu structure
Summary of Contents for MCE-22/P
Page 278: ...274 1 276 2 279 3 280 4 282 5 283 6 4 20 284 7 285 8 286 9 287 10 290 11 290 12 292...
Page 279: ...275 IEC 60634...
Page 280: ...276 1 6 MCE 22 P MCE 15 P MCE 11 P 1 1 1...
Page 282: ...278 2 5 2 1 2 1 2 2 1 1 2 1 2 L L L 2 2 4 15...
Page 283: ...279 2 2 2 1 2 2 1 1 3 1 LN 2 2 3 1 3 4 4...
Page 284: ...280 A 3 3 2 2 1 2 4 3 1 UVW 2 2 4 3 50 60 200 1...
Page 286: ...282 4 2 2 3 Press e Flow 5 A B C D d1 d2...
Page 291: ...287 3 9 64 X 128 4 MODE SET 9 7 MODE 1 SET 8 3 EEprom SET 6 SET MODE...
Page 292: ...288 3 1 9 3 2 1 2 3 2 1 MODE SET MODE 8 2 2 5 5 5 2 2 9...
Page 294: ...290 3 2 2 10 SET 10 15 12 11...
Page 296: ...292 12 12 12 GO SB...
Page 297: ...293 4 4 1 Link 8 4 2 4 2 1 Link 2 Link 5...
Page 300: ...296 4 3 1 2 1 4 3 1 3 SET MODE LA RC FN MS FS FL AC AE O1 1 O2 2 4 4 ET 6 6 9 FL...
Page 326: ...322 BL 10 6 24 24 30 LP 180 200 HP OT TE 100 C 85 C OB BT 120 C 100 C OC 10 6 OF 10 6 30...
Page 327: ...323 8 8 1 PMW 4 2 8 2 8 3 8 3 SET EE EEprom FLASH...
Page 494: ...490 1 492 2 495 3 496 4 498 5 499 6 4 20 mA 500 7 501 8 502 9 503 10 506 11 506 12 508 13 523...
Page 495: ...491 IEC 364 inverter...
Page 496: ...492 1 Inverter inverter inverter 6 inverter MCE 22 P MCE 15 P MCE 11 P 1 1 1...
Page 499: ...495 2 2 2 1 inverter inverter 2 2 1 1 inverter 3 1 LN 2 inverter 2 PVC 3 inverter 1 3 inverter...
Page 502: ...498 4 2 2 3 Press Flow 5 A B C D d1 d2...
Page 507: ...503 3 9 oled 64 X 128 4 MODE SET 9 inverter 7 MODE 1 SET 8 3 EEprom SET 6 SET MODE...
Page 508: ...504 3 1 9 3 2 1 2 3 2 1 MODE SET Setpoint MODE 9 ONOMA TOY MENOY 2 Setpoint 2 5 5 5 2 2 9...
Page 512: ...508 12 12 12 GO SB FAULT...
Page 543: ...539 8 8 1 PMW 4 2 8 2 inverter 8 3 8 3 inverter SET EEPROM FLASH setpoint...
Page 599: ...595...