DAC Monitoring and Control System
User Manual Data Logger and Tower Meter
DL-PDL_General-User-Manual
_ve_2-0-2.docx
Page 23
Caution:
A license key must be entered to configure Monitoring Points (sensors and rf-
detectors. In case the sensor configuration
cannot be saved
, this is an indication that the
amount of licensed Monitoring Points are exceeded.
Please add in the mask:
Type and serial number: the type and serial number of the DL/PDL you find on the label
on the back of the DL/PDL.
Give the DL/PDL a name acc. to your choice
Enter the site name acc. to the policy of the operator or your choice
Enter the GPS location data of the DL/PDL in following format: Grad (1..3 digits).decimal
value representing minutes, seconds (up to 8 digits) – google format; for conversion use:
http://www.csgnetwork.com/gpscoordconv.html
JB/PDL polling rate: shortest time - 4 seconds…3600 seconds
Set default alarm threshold for return loss (RL) or VSWR value of the sensors (for each
sensors an individual setting is possible)
9.3.2 Maintenance Mode configuration
The maintenance mode has been introduced to make sure that during maintenance the
NMC/OPC get no alarms and is confused about invalid data. The maintenance mode is flagged
to the operator with a blinking headline. During the Maintenance mode phase, the polling rate is
temporary switched to 4 sec.
Switch to the Maintenance Mode:
Clicking this button will activate the mode for
an indefinite time. By entering the Maintenance
Mode again, the Mode can be switched off at
any time.