DAC Monitoring and Control System
User Manual Data Logger and Tower Meter
DL-PDL_General-User-Manual
_ve_2-0-2.docx
Page 30
The forwarding of the Monitoring Data with traps in a network with hundreds of sensors and rf-
detectors with a short polling cycle of n times per minute could create a performance problem for
the NMS.
The MIB of this DL/PDL SW version can be collected here:
The DL/PDL – SW offers the current range of authentication and encryption methods.
Enter user name, password and encryption key of the connecting NMS/OMS system (SNMP
Manager).
For the transport UDP or TCP is selected. If the SNMP manager is supporting TCP, this is the
preferable selection.
With SNMP, the following values are forwarded to the SNMP Manager:
"Temperature, Multiplied with 10"
"Humidity, Multiplied with 10"
"PTx, Multiplied with 1000"
"PRx, Multiplied with 1000"
"Return Loss, Multiplied with 1000"
"VSWR, Multiplied with 1000"
Temperature value is always in Celsius, Humidity in percent.
SNMP version 3 has increased
security features. It requires to
configure the agent with
related
setting information of the SNMP
Manager
.