DAC Monitoring and Control System
User Manual Data Logger and Tower Meter
DL-PDL_General-User-Manual
_ve_2-0-2.docx
Page 39
Measurements with constant wave (CW) in FM range will be 0.2 dB higher
Pairing:
In this field a second port connected with an RF-interface is selected. Together the 2 ports act
like a sensor and the results are displayed in RL/VSWR value and the related measured power.
Clicking on the field “Switch Tx/Rx” allows to set the right port as Tx value.
Dashboard:
In this dashboard field, 2 modes can be selected, Auto or Manual:
Auto: In this case the gauge scale minimum and maximum is set acc. to the power
measured.
Manual: In this case both ends of the scale are manually set, with the split parameter the
split of the axe is defined.
Select another RF-
Interface port to pair the
2 measurements in a
RL/VSWR result.
After the selection an
individual threshold can
be set to alarm
degraded or failure
state of the RL/VSWR.
With a click on this
button the paired ports
can be switched to
assign Tx/Rx correctly.