Caution
The number of the RF-Detector and the related data need to consistent with the real Installation
in the cabinet. Example: The named RF-Detector
on port one (1) of the PDL/JB4.x
needs to be
equal to the data entered for the
RF-Detector one (1) of PDL/JB4.x edited in the RF-Detector
configuration menu and equal with the
physical connection of RF-Detector one (1) at port one
(1)
of the JB/PDL.
The fixed number of RJ45 ports is equal to the port number on the JB4.x/PDL.
In the field of the “JB-Name” the given name of the PDL/JB4.x is presented.
The configuration of the RF-Detector is divided into 5 fields, see the following description:
Field 1: General Data
Field 2: Alarm Thresholds
Field 3: Configuration Data
Field 4: Pairing
In case of
installation
variation, a
correction value
can be entered,
with +/- values.
Name the RF-Detector
acc. the directions of the
operator. Indicate with a
name the monitored
service (e.g. Channel 48).
Configuration Data:
Changing the operation frequency will
automatically adjust the Tx at the right
level, after the correct directional
coupling factor has been entered.
Choose the
correct RF-
Detector
type.
If a Temp./Humidity-
Detector is connected
to this PDL/JB4.x port,
click on this button
see for configuration
the next chapter.
In this
dashboard field,
2 modes can be
selected:
Auto by marking
the check box,
or Manual.