Note 3: Sensor sensitivity in the power range of the data sheet and with that the accuracy of the
measurement is limited; for this reason RL values above 35 dB or VSWR value below
1.036 are
not
displayed.
Note 4: The VSWR is displayed between 1.036 and 2.5.
Dashboard JB4.x
The dashboard gives an immediate overview about the monitoring information and system
status.
Choose the JB
and related
sensors/
detectors to be
displayed.
The number of
open alarms
per product
group is
visible.
Here the last sensor reading is
displayed. In case the polling time is
long, this indicates the actuality of
the measured data. Each blinking
indicates a polling cycle.
The attached
documents to
this JB are
shown. Click to
open.
Choose in the general data
Logger configuration mask:
Reverse gauge display
Return loss or VSWR
display
For each enabled Sensor
connected to the JB4.x, the
paired ports of the JB4.x are
displayed, and the related alarm
thresholds set (red range: urgent
alarm, yellow range: degraded
alarm, green range: ok).
The following values are
displayed per sensor below the
gauge meter:
Actual return loss - Note 3
Actual VSWR – Note 4
Measured Tx and Rx voltage
Actual PTx and PRx value –
Note1.
If the user is clicking on
the sensor display
automatically, the related
trend curve is shown.
For each enabled RF-
Detector, the RF-
Detector number and
related alarm thresholds
set, are displayed (red
range: urgent alarm,
green range: ok).
The following values are
displayed per RF-
Detector below the
gauge meter:
Measured Tx/Rx -
voltage
Actual PTx or PRx
value – Note1.
For each enabled
paired
RF-
Detectors, the RF-Detector
numbers and related alarm
thresholds set, are displayed (red
range: urgent alarm, yellow range:
degraded alarm, green range: ok).
The following values are displayed
per paired RF-Detectors, below
the gauge meter:
Actual return loss - Note 3
Actual VSWR – Note 4
Measured Tx and Rx voltage
Actual PTx and PRx value –
Note1.