DAC Monitoring and Control System
User Manual Data Logger and Tower Meter
DL-PDL_General-User-Manual
_ve_2-0-2.docx
Page 84
14.5 ATSB / Tx Interface
The ATSB / Tx interface controls one action towards the transmitter and is configured in this
mask.
Configuration of the ATSB interface:
Note 1
: The interface has 2 positions, position 1 and position 2.
The position number relates
to the relay output connection number
. Each position can be named, this name is
shown with the position reading.
Very importantly the default position
is selected and
relates to the rule condition NOT activated (everything ok).
Note 2: If the ATSB Interface is used in a rule, the interface cannot be disabled.
Interface Status line:
Name (default numbering)
Name of ATSB / transmitter
OID
SNMP address
Connection status
The result of each ATS polling cycle or
manual check is the status of the interface
with the corresponding name.
Green: Interface is in default position
Yellow: Interface is in non-default position
Red: Interface is inconsistent with the rule
Manual check of each
interface position of the
ATSB.
Enable each
interface, Note 2.
With double click the
interface configuration
menu is started:
Name (default No.)
OID (read only)
Interface logic
(Note 1
)
Click the Save button
to store the changes
made.
Double click
or front-line
selection
allows to
Edit or
Toggle
the
ATSB / Tx
interface.