17
F-05. Comparision mode (Comparision output mode setup)
(Standard setup value: 0)
Display data
Setting
0
Decision mode
: Relay RY1(Lo), RY2(Hi), RY3(Ok) Output
1
High limit mode
: Relay RY1, RY2, RY3 Output
2
Low limit mode
: Relay RY1, RY2, RY3 Output
F-06. Hysteresis
(Standard setup value: 00)
Display data
Setting
00
00
: Hysteresis not used
~
99
01 ~99 : Hysteresis used (Decision mode is not applied)
F-08. DAC zero (Analog Outupt value setup)
(Standard setup value : 10000)
Display data
Setting
-19999
Analog output capacity set-up
<If Setting value 10000>
Display
data
F-07 setting data
V_05V V_10V V_02A V_42A b_05V b_10V b_02A b_42A
-10000
-5V
-10V
0
4mA
0
0
0
4mA
0
0
0
0
4mA
2.5V
5V
10mA 12mA
10000
+5V
+10V 20mA 20mA
5V
10V
20mA 20mA
1
~
+99999
F-09. ID Number (Communication Device Number setup)
(Standard setup value: 00)
Display data
Setting
00
00
: Device number is not set-up(Stream mode:always transmit data )
~
32